Descargar Imprimir esta página

Clay Paky ALPHA SPOT QWO 800 Manual De Instrucciones página 32

Ocultar thumbs Ver también para ALPHA SPOT QWO 800:

Publicidad

• LAMP CONTROL (only with option LAMP DMX On) - channel: 32
IMPORTANT: Alpha Spot QWO 800 is not provided with hot restrike igniter
ON
ON
OFF
OFF
The functions are actived passing through the unused range and staying 5 seconds in
necessary level
"
"
ALPHA SPOT QWO 800 &
ST
BIT
%
EFFECT
255
100
LAMP ON (FULL POWER)
Lamp ignition after 5 s
in full power levels.
Immediate transition
from half to full power.
180
70.5
LAMP ON (FULL POWER)
UNUSED RANGE
179
70.0
101
39.5
UNUSED RANGE
100
39.0
LAMP OFF
Lamp switch off passing
throug the unused
range and staying 5 s in
Lamp OFF levels.
26
10.0
LAMP OFF
25
9.7
UNUSED RANGE
0
0.0
32

Publicidad

loading

Este manual también es adecuado para:

Alpha spot qwo 800 stC61380C61381