9.
Installation under traffic areas up to HGV60
Asphalt structure +
frost protection layer
Covering
EcoBloc
Inspect
system
Blinding
Traffic surfaces up to HGV60 should be structured according to prevalent guidelines (e.g. RStO 01 of the
Forschungsgesellschaft für Strassen- und Verkehrswesen research body). The blinding is preferably
made from gravel with a grit of 8mm/16mm and is 8-10 cm thick.
The EcoBloc Inspect system must be installed and connected in accordance with chapter 7. Ventilation
heads should be installed in green spaces.
9. Installation under traffic areas up to HGV60
HGV60
32 / 69
H
acc. RStO 01
AS
▼E
=45MN/m²
v2
H
R
▼E
=25MN/m²
v2
8-10cm