Use Of The Generator - Truper GEN-80X Manual De Instrucciones

Ocultar thumbs Ver también para GEN-80X:
Tabla de contenido

Publicidad

After being ON do not allow the jack-line handle for manual starting
to sharply get in place. Return it softly to its original position.
Starting the motor using the gear
Before starting the generator do not connect any power
device.
1. Turn the fuel tap to the
ON position (Open)
2. Set the choke lever on the
OFF (closed) position.
3. Turn the motor ignition key
to the START (Ignition) position.
4. Set the choke lever in ON (Open)

Use of the Generator

To avoid electric shock caused by defective devices
the generator should be grounded.
Connect resistant cables between the ground
outlet and the ground source. To avoid misuse
of the electric equipment the generator should
be grounded. We are not liable for damage to
the equipment or personal injury caused if this
safety measure is not obeyed before operating the
generator.
• A. C. connections in an electric system should be installed
by a qualified electrician and comply with all the applicable
electric laws and codes. Inadequate connections could
generate electric current feedback from the generator to
the utility lines.
• Current feedback could electrocute the users of the
circuits; even other people touching the lines during a
blackout could get electrocuted. When electricity is restored
the generator could explode, get burned or cause fire in the
electric system.
• The total load of the power equipment should not exceed
CLOSED
the generator rated power.
• When the generator is started, the power equipment,
OPEN
especially the conductor units will produce large ignition
current. The following table is a reference when connecting
power devices to your generator.
• To connect more than two loads into the generator,
connect the loads first the high current start and then the
low current start.
NOTICE
power supply previously to the connection of the generator
into the network.
A.C. outlet
1. Start the gas generator (Figure 7)
Fig. 7
2. Connect the device (Figure 8)
• Verify the devices are not exceeding the generator rated
load capacity more than 30 minutes and they do not exceed
the highest load capacity.
• If there is an important overload, the load thermal
protector will shut off. It is possible a marginal overload will
not shut off the load thermal protector but it will reduce the
useful life of the generator.
• If, because a circuit has an overload, the load thermal
protector shuts off, reduce the electric load in the circuit and
wait a couple of minutes before restarting the load thermal
protector.
GEN-80X
8,000 W
800 W
400 W
2,600 W
2,200 W
(Two-phases)
A qualified electrician should verify the household
7

Publicidad

Tabla de contenido
loading