5.4 Mounting the lamp
1.
This luminaire does not have a built-in device to disconnect it from the electric mains. Make sure to
electrically isolate the luminaire before installation or maintenance activities are performed.
2.
Use the mounting bracket to determine the location of the mounting holes.
3.
Drill the holes and secure the bracket using screws and wall plugs.
4.
Connect the power cable to the screw terminal. Make sure there is no strain on the cable; leave
sufficient slack.
Warning: if the power cable is damaged, it must be replaced by the manufacturer, his service agent, or
a similar qualified person in order to avoid any hazard.
5.
To point the lamp in the desired direction: loosen the hinges using a screwdriver.
6.
Tilt the lamp in the desired angle and tighten the hinges.
6.
Remote Control
Refer to the illustration on page 2 of this manual.
The remote control has three control blocks: the sensitivity block [1], the time block [2] and the mode
block [3].
Mode
First, select the mode
Daylight mode. The sensor will work both at day and at night.
Nightlight mode. The sensor will only work with a luminous intensity of < 50 lux.
Photocell mode. The lamp will automatically switch on when the luminous intensity
drops below 50 lux.
N/A
Manual override mode. The lamp is switched on all the time.
Flash mode.
SOS mode.
V. 03 – 03/04/2020