121850
DIGITAL DIAL GAUGE
Operating instructions
Specification
Resolution: 0.01 mm / 0.001 mm
Measuring range: 12.7 mm / 25.4 mm / 50.8 mm
Operating temperature: 0 - 40°
Power: Lithium battery CR2032 / 3.0 V
Digital output: RS232
Features
Digital LCD display
Zero position (ZERO)
Measuring mode REL / ABS
PRESET (input preset value)
Change mm / inch
Important information before using the dial gauge
1. Dirt on the measuring spindle affects its movement. If necessary, clean the
measuring spindle with a clean cloth. Under no circumstances should oil be
used to lubricate the measuring spindle.
2. If necessary, clean the housing with a dry cloth. In case of heavy soiling,
use a neutral-reacting solvent. Do not use organic solvents (such as benzine
or thinner) under any circumstances - this will damage the device and cause
it to malfunction.
3. Protect the data input port with the appropriate cover when not in use.
4. The dial gauge must be clamped in a suitable holding device (e.g. dial gauge
stand) with locating hole 8H7.
5. Unauthorised opening of the dial gauge will result in loss of the warranty.
Safety information
Use the dial gauge only at the permissible operating temperature
Protect the dial gauge against liquids and moisture
Do not drop the dial gauge on the floor
Protect the dial gauge against mechanical damage
The dial gauge must be disposed of in compliance with the regulations
Key:
1. Battery compartment
2. Display
3. Data output interface
4. ZERO / ON button
5. ABS / PRESET button
6. in / mm button / measuring direction
Comments:
In the following instructions, the meanings are as follows:
Briefly press
press button for less than 2 seconds
Hold down
press button for more than 2 seconds
Brütsch/Rüegger Werkzeuge AG, Heinrich Stutz-Strasse 20, Postfach, CH-8902 Urdorf, Tel. +41 44 736 63 63, Fax +41 44 736 63 00, www.neriox.tools, sales@brw.ch
1
6
5
Zero / ON button
1. T o switch the dial gauge on, briefly press the ZERO/ON button
2. T o switch the dial gauge off, hold down the ZERO/ON button
3. T o apply a PRESET value, briefly press the ZERO/ON button (only possible
in the ABS measuring mode)
more detailed description in instructions on ABS / PRESET button
ABS / PRESET button
ABS
1. T o change the measuring mode (relative / absolute) - briefly press the ABS/
PRESET button.
When the dial gauge is in the ABS measuring mode, the display shows „ABS".
When the dial gauge is in the relative measuring mode, the display „ABS"
disappears.
When the dial gauge is in the ABS measuring mode, a PRESET value (0 or anot-
her preset value) can be applied by briefly pressing the ZERO/ON button
PRESET - Value - Setting
1. T o enter a PRESET value - hold down the ABS/PRESET button. All digits
and the +/- sign are displayed.
The last digit flashes indicating that the value can be changed. With the
ZERO/ON button, the desired digit - which is to be changed - can now be
selected. By briefly pressing the button, the flashing digit moves to the left.
In the flashing digit, the desired value can be changed with the in/mm button.
y briefly pressing the in/mm button you can select the digits between 0
2
3
and 9. After this, briefly press the Zero/ON button to select the next digit to
be changed. After you have made the desired setting, hold down the ABS/
RESET button to save the entered value. Thus, the input value becomes the
absolute zero point.
in / mm button
1. By briefly pressing the in/mm button you can switch between the metric
unit system „mm" and the English unit system „in".
2. By holding down the in/mm button a positive or negative value „+ / -" can
be defined for the measuring direction.
4
Repairs
If the device is defective, please contact our
service centre