Adjusting Spray Pattern; Adjusting Spray Volume; Cleaning Chemical Tank And Discharge Tube - Echo MB-440 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Adjusting spray pattern

Adjusting spray volume

Cleaning chemical tank and discharge tube

Operating mist blower
The spray pattern can be adjusted from the straight stream to an
open spray by adjusting the position of collar.
Loosen collar nut (A) and pull collar (B) forward to obtain a
straight stream.
Push collar backward to obtain a wide spray.
The spray volume can be adjusted by lining up the number (A)
with mark as shown. The spraying volume is prescribed as fol-
lows.
Setting number
Discharge volume
MB-440 (L /min)
Discharge volume
MB-580 (L /min)
Keep nozzle at a distance of 70 cm far from plants to pre-
vent damage.
Make job done before diluted chemical depositing at the
bottom of the chemical tank..
Clean chemical tank and discharge tube after each use.
1.
Fill chemical tank with clear water and run the engine.
2.
Spray through nozzle for 2 to 3 minutes for cleaning.
3.
Close the valve (A).
4.
Stop the engine
5.
Open the valve.
6.
Remove the drain plug (B) and drain water.
7.
Reinstall the drain plug and close the valve.
Do not remove the drain plug wiht the valve open.
You will be exposed to chemicals.
15
1
2
3
1.1
2.1
3.2
1.1
2.2
3.4
NOTE
WARNING
4
4.3
4.6

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mb-580

Tabla de contenido