TECHNICAL DATA

Rated input .............................................................................
Output .....................................................................................
No-load speed ........................................................................
Self-drill screws up to max......................................................
Allen screws (key width) .........................................................
Dry wall screws up to max. .....................................................
Setting range of depth gauge .................................................
Universal reception .................................................................
Weight without cable ..............................................................
Noise information
Measured values determined according to EN 60745.
Typically the A-weighted sound pressure level of the tool is:
Sound pressure level (K = 3 dB(A)) ......................................
Sound power level (K = 3 dB(A)) ...........................................
Wear ear protectors!
Vibration information
Total vibration values (vector sum in the three axes)
determined according to EN 60745.
Vibration emission value a
h
Screwing ..............................................................................
Uncertainty K .......................................................................
WARNING
The vibration emission level given in this information sheet has been measured in accordance with a standardised test given
in EN 60745 and may be used to compare one tool with another. It may be used for a preliminary assessment of exposure.
The declared vibration emission level represents the main applications of the tool. However if the tool is used for different
applications, with different accessories or poorly maintained, the vibration emission may differ. This may significantly increase
the exposure level over the total working period.
An estimation of the level of exposure to vibration should also take into account the times when the tool is switched off or
when it is running but not actually doing the job. This may significantly reduce the exposure level over the total working period.
Identify additional safety measures to protect the operator from the effects of vibration such as: maintain the tool and the
accessories, keep the hands warm, organisation of work patterns.
WARNING! Read all safety warnings and all
instructions, including those given in the accompanying
brochure. Failure to follow the warnings and instructions
may result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference.
SAFETY INSTRUCTIONS
Wear ear protectors. Exposure to noise can cause hearing
loss.
Hold power tool by insulated gripping surfaces, when
performing an operation where the fastener may
contact hidden wiring. Fasteners contacting a "live" wire
may make exposed metal parts of the power tool "live" and
could give the operator an electric shock.
Appliances used at many different locations including open
air should be connected via a residual current device of
30 mA or less.
When inserting or removing screws the workpiece should be
securely held to prevent rotation.
Always disconnect the plug from the socket before carrying
out any work on the machine.
Only plug-in when machine is switched off.
Keep mains lead clear from working range of the machine.
Always lead the cable away behind you.
When working in walls ceiling, or floor, take care to avoid
electric cables and gas or waterpipes.
16
ENGLISH
DWSE 4000 Q
TKSE 2500 Q
.........................725 W ...........................725 W
.........................340 W ...........................340 W
....................0-4000 min
..................0-2500 min
-1
-1
..............................- ...............................6,5 mm
..............................- ................................10 mm
.............................4 mm
.......................± 3,8 mm ......................± 3,8 mm
.........................1/4" ..............................1/4"
..........................1,3 kg ............................1,4 kg
...........................98 dB (A) ......................98 dB (A)
.........................109 dB (A) ....................109 dB (A)
..........................2,9 m/s
.........................2,9 m/s
2
2
..........................1,5 m/s
.........................1,5 m/s
2
2
SPECIFIED CONDITIONS OF USE
The screwdriver is suited for setting dry wall screws when
fixing gypsum plaster boards to wood furring or metal
furring.
Do not use this product in any other way as stated for
normal use.
MAINS CONNECTION
Connect only to single-phase a.c. current and only to the
system voltage indicated on the rating plate. It is also
possible to connect to sockets without an earthing contact
as the design conforms to safety class II.
EC-DECLARATION OF CONFORMITY
We declare under our sole responsibility that this product is
in conformity with the following standards or standardized
documents. EN 60745, EN 55014-1, EN 55014-2,
EN 61000-3-2, EN 61000-3-3, in accordance with the
regulations 98/37/EC, 2004/108/EC
Rainer Kumpf
Winnenden, 2008-04-28
Manager Product Development
MAINTENANCE
The ventilation slots of the machine must be kept clear at all
times.
Use only Milwaukee accessories and Milwaukee spare
parts. Should components need to be replaced which have
not been described, please contact one of our Milwaukee
service agents (see our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered.
Please state the Article No. as well as the machine type
printed on the label and order the drawing at your local
service agents or directly at: Milwaukee Electric Tool,
Max-Eyth-Straße 10, D-71364 Winnenden, Germany.
SYMBOLS
Please read the instructions carefully before
starting the machine.
Always disconnect the plug from the socket
before carrying out any work on the
machine.
Do not dispose of electric tools together
with household waste material! In
observance of European Directive 2002/96/
EC on waste electrical and electronic
equipment and its implementation in
accordance with national law, electric tools
that have reached the end of their life must
be collected separately and returned to an
environmentally compatible recycling
facility.
ENGLISH
17

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Tkse 2500 q

Tabla de contenido