31. Install the Seat
Remove the thumb screw, stainless steel washer, and rubber washer from the seat.
Slide the seat onto the bracket as shown.
Install the stainless steel washer, then the rubber washer onto the thumb screw.
Insert the thumb screw through the bracket's center slot and into the threaded hole in the seat
channel. Securely hand tighten the thumb screw.
32. Water Test the System
Allow the silicone sealant and any finished wall materials or grout to fully cure before proceeding.
Follow all manufacturer's recommendations regarding water exposure to their products, as well as
product cure times.
Make sure all PVC union connections are securely hand tightened and that all union connections
use an O-ring.
Fill the footbath basin at least 3" (7.6 cm) above the top of the suction cover.
Turn on the system for about five minutes and check all visible connections for leaks. Turn off the
system.
Open the tower and inspect all piping connections for leaks.
Close the tower. Securely wrench tighten the two 3/8" bolts. Do not overtighten.
33. Clean Up After Installation
Clean the hydro-massage system room with a mild non-abrasive detergent and warm water. Do not
use abrasive cleansers.
Remove stubborn stains and paint from the tower surfaces with turpentine or paint thinner. Remove
dried plaster by carefully scraping with a dull-edged piece of wood. Do not use metal scrapers, wire
brushes or other metal tools.
Remove residual plaster by applying a powder-type detergent to a clean, damp towel to provide
mild abrasive action.