6. TO REPLACE FILTER ELEMENT:
a. Depressurize unit.
b. Remove bowl and bowl guard assembly by turning counterclockwise.
c. Unscrew baffle by turning counterclockwise.
d. Remove filter element and discard.
e. Install new filter element and reassemble in reverse order. Torque
baffle to 8-10 in. lbs (0.90-1.1 N-m).
f. Before returning to service, insure that all seals have been
reinstalled or replaced.
g. Reinstall bowl and bowl guard assembly and rotate bowl guard
clockwise to securely lock in place. Align arrow on bowl guard with
arrow on filter/regulator body.
7. Filter element should be replaced when pressure drop across the unit
exceeds 10 psi (0.7 bar) differential pressure.
8. DRAIN BOWL DAILY to remove liquid water, oil and solid particulates
that have accumulated in the bowl reservoir.
ACCESSORIES
T-Type Bracket ......................................................................... GPA-96-737
C-Type Bracket ......................................................................... GPA-97-010
L-Type Bracket ......................................................................... GRP-96-739
Joiner Set .................................................................................. GPA-96-738
Piping Adapter Set, 1/8" NPT ................................................... GPA-97-018
Piping Adapter Set, 1/4" NPT ................................................... GPA-97-019
Piping Adapter Set, 3/8" NPT ................................................... GPA-97-020
Piping Adapter Set, G 1/8 ........................................................ GPA-97-065
Piping Adapter Set, G 1/4 ........................................................ GPA-97-066
Piping Adapter Set, G 3/8 ........................................................ GPA-97-067
Piping Adapter Set w/T-Bracket, 1/8" NPT .............................. GPA-97-025
Piping Adapter Set w/T-Bracket, 1/4" NPT .............................. GPA-97-026
Piping Adapter Set w/T-Bracket, 3/8" NPT .............................. GPA-97-027
Piping Adapter Set w/T-Bracket, G 1/8 .................................... GPA-97-068
Piping Adapter Set w/T-Bracket, G 1/4 .................................... GPA-97-069
Piping Adapter Set w/T-Bracket, G 3/8 .................................... GPA-97-070
Panel Mount Nut (Aluminum) ................................................... RPA-96-733
Panel Mount Nut (Plastic) ........................................................ RPA-96-734
Tamper Resistant Kit ................................................................ RPA-96-735
Safety Lockout Valve, 1/8" NPT .............................................. V08-01-0000
Safety Lockout Valve, 1/4" NPT .............................................. V08-02-0000
Safety Lockout Valve, G 1/8 ................................................... V08-C1-0000
Safety Lockout Valve, G 1/4 ................................................... V08-C2-0000
Diverter Block, 1/8" NPT ......................................................... N08-01-0000
Diverter Block, 1/4" NPT ......................................................... N08-02-0000
Diverter Block, G 1/8 .............................................................. N08-C1-0000
Diverter Block, G 1/4 .............................................................. N08-C2-0000
Diverter Block (w/check) 1/8" NPT ......................................... N08-01-C000
Diverter Block (w/check) 1/4" NPT ......................................... N08-02-C000
Diverter Block (w/check) G 1/8 .............................................. N08-C1-C000
Diverter Block (w/check) G 1/4 .............................................. N08-C2-C000
!
Polycarbonate bowls, being transparent and tough, are ideal for use with
Filters and Lubricators. They are suitable for use in normal industrial
environments, but should not be located in areas where they could be
subjected to direct sunlight, an impact blow, nor temperatures outside of the
rated range. As with most plastics, some chemicals can cause damage.
Polycarbonate bowls should not be exposed to chlorinated hydrocarbons,
ketones, esters and certain alcohols. They should not be used in air systems
where compressors are lubricated with fire-resistant fluids such as phosphate
ester and di-ester types.
Metal bowls are recommended where ambient and/or media conditions are
not compatible with polycarbonate bowls. Metal bowls resist the action of
most such solvents, but should not be used where strong acids or bases are
present or in salt laden atmospheres. Consult the factory for specific
recommendations where these conditions exist.
TO CLEAN POLYCARBONATE BOWLS USE MILD SOAP AND WATER
ONLY! DO NOT use cleansing agents such as acetone, benzene, carbon
tetrachloride, gasoline, toluene, etc., which are damaging to this plastic.
Bowl guards are recommended for added protection of polycarbonate bowls
where chemical attack may occur.
CAUTION
83-714-000