WIKA XTRACTO-PAD TC59-X Manual De Instrucciones página 13

Ocultar thumbs Ver también para XTRACTO-PAD TC59-X:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6. Commissioning, operation
Figure 1: Welding details
Fillet
weld
Fillet
weld
6.9 Tube clip welding
Attach clips at predetermined locations. Preheat area before welding, if required.
Weld the first tube clip at 100 mm (4") from the guide channel, weld only on the opposite
side of the guide channel (see figure 2).
Weld tube clip on one end only and ensure there is a loose fit (no friction)
between the mineral-insulated cable and the clip.
The tube clip should allow axial expansion of the mineral-insulated cable.
Weld clips maximum every 300 mm (12") to 450 mm (18") of run (see figure 2) alternating
on opposite sides of the sheath.
Force tube clips down after the thermocouple installation to ensure good sensor to tube
contact.
Figure 2: Tube clip welding
Fillet
weld
WIKA operating instructions model TC59-X (XTRACTO-PAD
First clip
maximum
100 mm (4")
Maximum
300 mm to 450 mm
(12" to 18")
MI
cable
Fillet
weld
)
EN
13

Publicidad

Tabla de contenido
loading

Tabla de contenido