• Programming the operator
14
Control elements
The controls for programming the door operator are
protected by a transparent cover. The transparent
cover can be opened with a screwdriver. After the
operator has been programmed, the transparent
cover must be closed again.
A
. Numerical display shows the menu stage as well
as the selected value.
a.
Point display, lights up to indicate "ready for
operation" and flashes on the hand transmitter
code learning completion.
B
. Button
during the setting / adjustment phase
serves as an "up" button and outside the menu as
a start button.
C
. Button
during the setting /adjustment phase
serves as a "down" button.
D
. Button
is used to call up the setting/adjustment
menu, to change the menu stages and to store the
settings.
The programming of the control unit is menu-driven.
By pressing button
, the menu guide is called up.
The numbers displayed indicate the menu stage.
After approx. 2 seconds, the display flashes and the
setting can be altered via buttons
selected setting is stored with button
programme jumps automatically to the next menu
stage. By repeatedly pressing button
stages can be skipped. To quit the menu, press
button
until "0" is shown again. Outside the menu,
button
can be used to generate a start impulse.
Before programming
- Allow door to engage into the carriage.
- Pull out the mains plug. Point display (a) lights up.
- Make sure that the aerial is correctly positioned
(see figure 13).
- Observe the hand transmitter instructions.
15
Menu stage 1: Programming the start
function for the hand transmitter
Briefly press button
. "1" is displayed. As soon as
the display flashes, press and keep pressed for
approx. 1 second the button of the hand transmitter,
with which you later wish to start the operator. As
soon as the code has been read, the red point
display (a) flashes four times before quitting.
0 will be displayed. Menu finished.
Further hand transmitters (up to a maximum of 30)
can be programmed.
16
Menu stage 2: Programming the light
function for the hand transmitter
Press key
briefly and figure 1 will be displayed.
Press key
once again and figure 2 will be
displayed.
Press the second button at the transmitter with which
the 4-min light is to be switched on. As soon as the
code has been read in, the red point display (a) will
flash four times to acknowledge the entry. Figure 0
will be displayed. Menu finished.
Deleating all the hand transmitters programmed
for the operator:
Plug in the operator's main plug while pressing
button
.
17
Menu stage 3: Setting/adjusting the top end-
of-travel position
Keep button
pressed for 3 seconds. Number 3
appears in the display 8 a.
Wait a short while until the 3 starts flashing.
Press button
and make sure that the door travels in
the OPEN direction.
If the door closes in the wrong direction, after
!
having pressed
, keep button
another 3 seconds. "3" flashes briefly. The
Retain these installation, operating and maintenance instructions for the full duration of the operator's service life!
travelling direction is altered.
Now travel by pressing button
end position OPEN 17b.
By pressing button
into direction CLOSE.
Once the desired OPEN end-of-travel position has
been reached, press button
the OPEN end-of-travel position and "4" appears in
the display.
18
Menu stage 4: Setting/adjusting the bottom
end-of-travel position
Wait a short while until "4" starts flashing.
Press button
. The operator causes the door to
travel in the CLOSE direction as long as the button is
pressed. The position can be altered to the OPEN
direction via button ..
Once the desired CLOSE end-of-travel position has
been reached, press button
the CLOSE end-of-travel position and "0" appears in
the display.
19
Force-learning cycle
We recommend setting the suitable door type in
!
and
. The
menu stage 8 prior to the force-learning cycle.
. And the
During this opening and closing cycle, the
, menu
operator learns the force required to open and close
the door.
A force limit does not apply!
must not be interrupted. During these cycles must
not be interrupted. During these cycles "0" appears
in the display.
- Press button . The operator causes the door to
open until the top end-of-travel position has been
reached.
- Now press button
the door to close until the bottom end-of-travel
position has been reached.
- After approx. 2 seconds, "0"disappears.
Caution!
If the force setting is too high, persons may
be placed at risk of injury.
The factory setting is 4!
20
Figure
Checking the force limit facility
- Place an obstruction (e. g. operator's cardboard
box) underneath the doors's closing edge.
- Starting from the OPEN end-of-travel position,
19
actuate the door to close.
- The door travels towards the obstruction, stops
and travels back to the top end-of-travel position.
If the door springs have been changed or altered,
then the force learning cycle must be repeated:
proceed to menu stage 5 and keep button
pressed for 3 seconds. "0" appears in the display.
Then complete the force learning cycle as explained
under point 19.
• Special settings
In order to access the menus for the special settings,
keep key
pressed for 3 sec until figure 3 is
displayed. Press key
Now keep key
displayed. Press key
Menu stage 5: The opening force limit
pressed for
After approx. 2 seconds, the display flashes showing
the set value of the opening force limit. The force limit
into the desired door
, the position can be corrected
. The operator stores
. The operator stores
The cycles
again. The operator causes
to by-pass menu step 3.
pressed for 3 sec until figure 5 is
to by-pass menu steps.
setting can be increased or decreased via buttons
and . After setting the value, press button
The display shows "6".
Menu stage 6: The closing force limit
After approx. 2 seconds, the display starts flashing,
and the set value for the closing force limit is
displayed.
The force limit setting can be increased or decreased
via buttons
and .
After setting the value, press button
in the display.
Finally, check the force settings, and, if necessary,
repeat the setting procedure.
The maximum force at the main closing edge must
not exceed 150 N!
Menu stage 7: Light phases
Keep button
pressed again for 3 seconds until
"7" appears in the display.
Menu
Light
Warning
value
phase
phase
0
60 s
-
1
120 s
-
2
240 s
-
3
0 s
0 s
4
0 s
3 s
5
0 s
0 s
6
0 s
3 s
7
90 s
3 s
8
90 s
3 s
9
0 s
10 s
When the advance warning time is set, the light will
flash before the operator starts running.
The factory setting is 1.
Menu stage 8: Door fitting
Press button
. "8" appears in the display.
Menu
Start
Stop
Start
value
open
open
closed
0
0
0
0
1
15
0
15
2
0
15
0
3
15
15
15
4
25
30
25
5
15
15
15
6
15
15
15
7
35
35
65
8
55
15
15
9
only soft run
These values correspond to the "soft" runs
measured in cm at the carriage.
Important note:
The factory setting of 4 must be adhered. The
softruns may only be alerted on the express per-
mission of the door manufacturer.
Press button
. "0" appears in the display.
GB
.
. "0" appears
Flashing
function
-
-
-
yes
-
-
yes
-
yes
yes
Stop
closed
0
0
40
35
40
55
15
45
100