Technical Data - aqua technix Majestic Timer Traducción De Las Manual Original

Bombas de circulación, auto-aspirantes
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

8. Repairs
Repair are only to be done by an authorized service
center.
9. Recommendations
Caution
Only install the pump in a lockable room, out of the reach of
children.
Ensure the motor's cooling. The installation site must be dry and
well ventilated.
Never obstruct the air supply to the fan by putting any objects on
the pump or too close to the pump.

10. Technical data

Technical data at 50 Hz
Inlet Sa / outlet Da d (mm)
Rec. inlet / outlet. PVC-pipe. d
Power input P
(kW)
¹
Power output P
(kW)
²
Rated current (A)
Weight (kg)
Type of motor enclosure
Class of insulation
Motor speed approx. (rpm)
Max. continuous sound pressure
level dB(A)
Max. water temperature (°C).
Max. casing pressure (bar)
* Explanation of water temperature 40 (60) °C:
40 °C: max. water temperature as certified by the GS approval.
(60 °C): pump in its current design is however usable/designed for a max. water temperature of 60 °C.
Subject to technical modifications!
!
Majestic
1~ 230 V
1~ 230 V
1~ 230 V
1~ 230 V
IP 55
B/F
2840
70
1)
40 (60)*
2.5
Timer 6
50 / 50
50 / 40
0,50
0,25
2,30
6,60
For standard voltage according to DIN IEC 60038 and
DIN EN 60034 (Euro voltage).
Suitable for continuous operation at 1~ 220-240 V
and 3~ Y/Δ 380-420 V/220-240 V.
Tolerances ± 5%
1)
Measured with a phonometer according to DIN 45635.
.
Timer 9
Timer 12
50 / 50
50 / 50
50 / 40
50 / 50
0,65
0,83
0,40
0,45
2,90
3,60
7,50
7,60
W91.40.622-P
W91.40.623-P