Pilot Light - Tecnoinox FTL4G9 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 34
Part 2
To convert the appliance to another type of gas (e.g. from natural
gas to LPG), the nozzles of the main burner, of the by-pass and of
the pilot light have to be changed. All nozzles are marked with a
number that indicates the diameter in 1/100 and are supplied in a
bag.
Connections to the distribution network, installation, and maintenance of the appliance must be carried out only by qualified
personnel, in observance of all applicable regulations!
BURNER:
Pull the knob/s off.
Remove the control panel by unscrewing the fixing screws, then
locate the burner.
Replace the "U" nozzle (pic.5) with another one, suitable for the
new type of gas indicated in the nozzles table - T1 in the
section Specifications.
ADJUSTING THE AIR:
Unscrew the fixing screw "X" (pic.5) of the bush of each burner
and adjust the primary air by moving it up to the distance
indicated in the nozzles table reference "H" (pic.5); then screw
Replacing the nozzles and adjusting the air
GB / IE - 3
After each conversion or adaptation, the appliance must undergo an
operating test and the supplementary data plate must be updated on
the basis of the conversion or adaptation carried out.
the fixing screw in and reassemble the parts of the appliance, as
they were in their original condition.

PILOT LIGHT:

Replace the pilot nozzle "D" (pic.3) after having pulled out the
closing nut.
MINIMUM (only on models FTR and FTL):
Unscrew and replace or adjust the minimum by-pass nozzle
"Um" (pic.6) on the basis of the indications in the nozzles table
T1 section Specifications.
Reassemble the control panel.
Reassemble the knob/s.
Conversion and adaptation
5410.289.00

Publicidad

Tabla de contenido
loading