Remote Control; Preparing For Installation - Sulion CAMBIL Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 1
Due to the fan's movement, certain fastenings may become loose. Check all fastenings twice per year at a
minimum in order to ensure that they are sufficiently tight. If necessary, they must be retightened.
If the power cord is damaged, it must be replaced by the manufacturer, its after-sales service or similar
qualified personnel in order to avoid any malfunction.
Only suitable for indoors.
Replaceable bulb / Replaceable LED
Replaceable driver
Replaceable receiver
Do not throw away electrical products together with household waste. We ask you to recycle the packaging
at the collection points provided for this purpose. Contact local authorities or your provider for recycling
advice. Thank you for recycling at the collection points provided for this manual.
Note: The important warnings and instructions indicated in this manual are not guaranteed to cover all possible conditions
and situations that may occur. It must be understood that common sense, precaution, and care are factors that cannot be
included in all products. These factors can and must only be provided by the user who maintains and enjoys this fan.
Device technical spectifications
Nominal voltage and frequency
Light wattage
Luminous flux
Light color temperature
Nº of light ON/OFF cycles
Nº of hours of light lifespan
Protection category
Protection index
Word temperature
10
Dimmable/Not dimmable
Light angle
Light Ra
Weight
This product have a light source of energy efficiency class
Speed
Fan power (W)
Fan RPM
Fan airflow (m³/min)
Noise level (dB)
Service value SV ((m³ / min) / W)
Power consumption in standby mode (W)
Service value measurement standard

Preparing for installation

Note: The estimated installation time is 120 minutes. This product can only be installed by a certified electrician Carefully
separate the fan's parts, avoiding the use of cutters or blades that could scratch any part of it.
CIF A28763647
220-240V~AC 50/60Hz
1
2
3
5
5.5
8
600
730
830
61
77
92.5
20
30
35
12.2
11.8
11.5
10.8
+34 916774540
Calle Verano, 51 - Polígono Industrial Las Monjas -28850 Torrejón de Ardoz - Madrid (ESPAÑA)

Remote control

3 3
2 2
S S T T OP
OP
1 1
+ +
ON/OFF
ON/OFF
- -
1H
1H
44W
2800 lm
3000-6000K
Syncing the receiver and the remote control for fan operation
10000
If the receiver and transmitter of this fan are properly synchronized, the fan will work. During synchronization the receiver
35000h
recognizes the signal from the transmitter, this is called the learning process.
Class I
Make sure the fan is disconnected. This is essential for the synchronization process.
IP20
Unless the synchronization process has been successful, the fan will work partially or will not work. By default, all fans have
been preconfigured at the factory and should be functional once the installation is completed and the fan is turned on.
-5
40ºC
If the remote control does not work after installation or during use, synchronization can be performed as indicated below. Note
Dimmable
in any case that there could be other reasons why your fan or remote control does not work:
230º
Make sure all connections are correctly made.
Make sure that the remote control contains batteries.
>80
Make sure that all switches (main and isolation) are on.
3,2kg
Instructions for synchronizing the receiver and the remote control
G
The control of this fan does not require synchronization with the recelver, the control is already factory-linked with its receiver;
Universal mode and Unit mode:
- Unit Mode:
This type of synchronization allows you to control two or more nearby fans independently, each with its remote control.
Synchronization:
4
5
6
The control of this fan does not require synchronization with the receiver, the control is already factory-linked with its receiver
10
13
16
- Universal Mode:
This type of synchronization allows you to control one or more nearby fans with the same remote control.
950
1050 1140
Synchronization:
108
123
145
1.-Connect the power (wall switch) of the fan or fans that you want to control, and then just within the following
40
45
50
5 seconds, press the key
9.4
7.6
2.-A flash light indicates that the connection has been executed and the equipment can function normally.
3.-Now, transmitter and receiver of the fan / s will have been synchronized. Turn off the fan / s current using the
<0,5
switch or automatic and then turn it back on / s, this step is the one that closes the synchronization process.
EN 62879:2020
It is not possible for a controller to forget a fan once it has been linked, if you want a fan to leave
to obey a command, another one must be linked to "overwrite it".
ATC: 916749481 - info@sulion.es / SAT : 916749483 - sat@sulion.es
ALL OFF
-
CHANGE SENSE OF ROTATION
4 4
ON/OFF FAN
5 5
S S T T OP
OP
6 6
CHANGE LIGHT INTENSITY
- -
+ +
K+
K+
CHANGE COLOR TEMPERATURE
K+
K+
K K - -
ON / OFF FAN
K K - -
ON/OFF
ON/OFF
2H
2H
TIMING FUNCTION
1H
1H 2H
2H
CHANGE COLOR TEMPERATURE 3000/4000K/6000K
SPEED FAN
1/2/3/4/5/6
of the remote control for 5 continuous seconds.
ON/OFF
ON/OFF
11
www.sulion.es

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

075766

Tabla de contenido