Error Messages - dirna Bergstrom bycool green line DINAMIC 1.1 24V Manual Del Usuario

Ocultar thumbs Ver también para bycool green line DINAMIC 1.1 24V:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

DINAMIC 1.1
EN
The condenser fan and compressor connect and disconnect automatically when the chosen
temperature is reached. (e.g. chosen temperature 23º, the compressor and the condenser
fan disconnect at 21º and reconnect at 24º).
It indicates temperature inside vehicle. In this functioning mode, equipment is switched off.
Hours de functioning and switching off from 0 to 9 hours. On 0 hour, it does not temporise, it
is in manual functioning F0.
To select hours, user will employ
Choose hour which appears on display, 1H (one hour), 2H (two hours)....9H (nine hours),
and push ON/OFF
and will stop when this time period is over.
!
If when equipment is switched on, it makes continuous noises, it means that
keyboard is badly connected or not connected.
E0 - Return air sensor failure.
E1 - Low battery, less than 22.8V.
E2 - Condenser or blower fan failure.
E3 -
Compressor failure (Causes: engine, wiring, connector, lack or excess of charge)
E5 - Compressor electronic module failure due to heating.
E6 - Anti-ice probe failure.
!
In some cases of mistake message, to swith off the unit keep the ON/OFF
button
pushed till the screen switches off.
F1 Digital thermometer module
F2 Time programming
keys.
select F4 ó F0 , equipment will be working during selected time

Error messages

10
Air conditioning for vehicles
Important

Publicidad

Tabla de contenido
loading

Tabla de contenido