1.
If the spout connecting hose is too long, cut it to the appropriate length, making
sure the end is square. (see Ill. 1).
2.
Push the spout connecting hose onto the outlet barb of the controller and secure
it with the hose clamp (see Ill. 2). Make sure that the hose clamp is placed fully
against the controller.
3.
Connect the backup battery connector to the controller. Make sure there are no
obstructions between the sensor and the basin, then connect the spout sensor
connector to the controller. (see Ill. 3)
IMPORTANT!
The faucet will begin an automatic sensing range adjustment immediately after the
sensor connector is plugged into the controller. Do not place your hands or other
objects in front of the sensor.This process may take up to 20 seconds to complete.
• If the sensor light continues to fash for more than 20 seconds, the spout direc -
tion will need to be readjusted for proper operation. If adjustment is necessary,
you must do it within 10 minutes or the adjustment p rocess will end. To restart the
process, unplug the sensor connector for 10 seconds, then reconnect it.
4.
Double-check all connections, then re-install the controller cover, securing it with
the screws.
WARNING : Draw the sensor cord from the bottom of the controller while installing the
controller cover to ensure that the cord is not pinched.
Ill. 1
Cutting Length
Spout Connecting
Ill. 3
INSTALLATION PROCEDURE
Connect the Spout to the Controller
90°
Hose
Sensor
connector
Ill. 2
Spout
Connecting
Hose
Hose
Clamp
Ill. 4
6
Clamp fush
with
controller
Sensor
Sensor
Light