1.7 Front Panel Explanations

On the front panel You can found 1LED for an easy diagnostic.
LED/Switch
Main Switch
LED Line
Information
To Control on/off the UPS when Utility is normal. Push
the "Main Switch", then release it.
To enable "DC-Start" Function when Utility fails. (To
enable DC Start properly, you are recommended to
connect <80% output load with the UPS only). P.S.
Make sure the computer connected to the UPS is
switched on before enable the "DC-Start" function.
You are not recommended to add some other
computer or peripherals after DC-Start function is
activated.
AC Mode: Green LED remains standstill when Utility is
normal.
Battery Mode: Green LED flashes every 10 seconds
and simultaneously buzzer alarms (beep once every 10
seconds) continuously when Utility failure.
Low battery at battery mode: Green LED flashes
once every 1 seconds and simultaneously buzzer
alarms (beep once every 1 seconds) continuously
when utility failure and battery is Low.
Green OFF: to avoid UPS from over-discharge, the UPS
shuts itself down when the battery voltage is too low,
then Plug the UPS into the wall outlet to charge the
UPS for over 8 hours before using the UPS.
26
ENG