INSTALLATION INSTRUCTIONS
Connecting Electric Dryers (cont.)
USA only
WARNING
Three-wire connection for electric dryers:
Power cord
upper back of the dryer. Install a UL-listed strain relief
into the power cord through-hole; then thread a UL-
listed,
conductor power cord through the strain
relief.
UL-Listed
Cord
Terminal
UL-Listed
Strain Relief
forked terminals with upturned ends.
outer terminal block screws. Attach the neutral wire to
the center terminal block screw. Connect the external
ground screw.
Reinstall the terminal block access cover.
Hot
Ground
Screw
White Wire
from Dryer
harness
External Ground
conductor and closed loop or
Neutral
Hot
.