Lincar Milly 515SC Manual Del Usuario página 48

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

IT-GB-FR-ES mod. 515SC
EQUIPMENT REGULATION
REGULATION Room Temperature
To set up the room temperature means to put a limit to
the heating of the appliance, if the room temperature
overcomes the set up value ( i.e..20°) the appliance will
automatically reduce the power putting it to minimal
power ( power 1) to avoid waste of combustible. .
- On the display push P1 or P2
- Regulate the required temperature with P1 and P2
- When the regulation of room temperature is finished, push briefly P3 and the new
temperature will be memorized and the display will return on previous page.
REGULATION Equipment Power.
The appliance can be regulated on 5 power levels. (1-min , 5-max). We recommend the power
3 for the first functioning hours.
The appliance will utilize the set up value as maximal value for the heating functioning, it's
possible in this way to limit the max equipment power.
Anyway, if the room temperature will reach the set up value,
the appliance will reduce automatically the power
(modulation) to avoid waste of combustible.
- In the first display/page push P5 and P6
- To regulate the installation power employing P5 or P6.
- When the regulation of equipment power is finished, push
briefly P3 and the new power will be memorized, the display will return on previous page.
STARTING CYCLE
1° Lighting (new equipment or every time the tank is empty of fuel)
- Put the fuel into the container and switch on the appliance
-In case the display is signalling an alarm keep the push button
P4 pressed
-In case the display is signalling "Final cleaning" wait until on
the display appears "Off" (approx. 10/15 minutes)
- Appliance in switched off condition display "OFF
- Push on P3 to enter to the program menu.
- Push P5 or P6 to go on MENU 07
- Push P3 to go to the menu initial load
- Push P1 to activate the start of 90 seconds of screw feeder
- Once the pellet has started to fall into the burner basket press
on button P4 to stop the fall of fuel into the burner basket.
If necessary, repeat this operation several time until the pellet
falls down in the burner basket.
48/124

Publicidad

Tabla de contenido
loading

Tabla de contenido