before retrying the ignition sequence.
10. If the burner does not stay alight, please repeat step 8.
11. When the burner is lit. Adjust the heat by turning the knob to the High/Low position.
12. To turn 'OFF' the barbecue, turn the cylinder valve or regulator switch to the 'OFF' positi-
on by following the regulator instructions, turn all of the control knobs on the appliance
clockwise to the "OFF" position when the flame have extinguished.
WARNING
If any burner fails to ignite, turn the control knob off (clockwise) and also turn the cylin-
der valve off. Wait five minutes before attempting to relight with ignition sequence.
After use, close the gas supply by either turning 'OFF' the switch on the regulator or tur-
ning 'OFF' the cylinder valve.
In the event of light back whilst the appliance is in use. Turn all the controls, cylinder
valve and regulator switch to the 'OFF' position. Wait 5 minutes before attempting to
relight the appliance. If the problem persists after relighting, consult your gas dealer, or
the store where you purchased the barbecue, or a qualified gas engineer for assistance or
repair. Never try to rectify the problem yourself as this could result in serious injury and/
or property damage.
Clean the appliance of excess fat, before storage, with a damp cloth using a mild deter-
gent solution as the cleaning agent.
Store the appliance in a clean dry environment.
Do not store your gas cylinder indoors. Store in a well ventilated area away from direct
sunlight.
CONNECTING THE GAS CYLINDER TO THE APPLIANCE
This appliance is only suitable for use with low-pressure butane ,propane or their mixture
gas and used with the appropriate low-pressure regulator via a flexible hose. The hose
should be secured to the regulator and the appliance with hose clips.
Using 28mbar regulator with category I3+ for butane gas and a 37mbar regulator with
category I3+ for propane gas.
Using a 30 mbar regulator with category I3B/P(30).
Using a 37 mbar regulator with category I3B/P(37).
Using a 50 mbar regulator with category I3B/P(50).
Use a suitable regulator certified to BSEN 12864:2001.
Please consult your LPG dealer for information regarding a suitable regulator for the gas
cylinder.
BEFORE USE PLEASE CHECK FOR LEAKS
Never check for leaks with a naked flame, always use a soapy water solution
TO CHECK FOR LEAKS
Make 2-3 fluid ounces of leak detecting solution by mixing one part washing up liquid
with 3 parts water.
Ensure the control valve is "OFF".
Connect the regulator to the cylinder and connect regulator with hose and outdoor gas
grill, ensure the connections are secure then turn ON the gas.
Brush the soapy solution on to the hose and all joints. If bubbles appear you have a leak,
which must be rectified before use.Turn off the gas supply in the event of gas leak.
Retest after fixing the fault. Turn OFF the gas at the cylinder after testing.
If detected leakage can not be rectified, do not attempt to cure leakage but consult your
gas dealer.