Master audio Xcellence Serie Manual Usuario página 17

Ocultar thumbs Ver también para Xcellence Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Master Audio
XLR-3 Male connector for parallel connection of various cabinets with the same input
signal.
IMPORTANT: Please always use balanced microphone cable with the following pin
assignment:
1= Shield (Ground) 2= Live (+)
H) AC INPUT/OVERVOLTAGE PROTECTION: These leds show the status of the
AC mains supply.
• ON: (Blue) When lit, the equipment is ON and the AC input level is within the
permitted range (up to 250 VAC).
• STANDBY: (Orange) This led is lit when the equipment is sensing the AC
voltage at the input. At power-up this led will lit for a second while the systems
checks for the input voltage.
• >250V OVERVOLTAGE PROTECTION: (Red) When activated, the AC
voltage is permanently out of the permitted range of the equipment
(>250VAC), so it will remain under protection until this condition is solved.
Revise your connections and mains power installation and consider that other
equipment connected to this line may have been damaged.
I) AC MAINS INPUT/LINK: Mains supply connection via PowerCon.
• Blue connector for AC in.
• Grey connector to feed other units in parallel. Linking up to 2 units is possible,
provided that a quality cable of a minimum section of 3x2,5 mm
Connecting more than 2 units in parallel may lead to a voltage drop in the cable
that will reduce the equipment performance.
A
Fig.10. X18WE control and connection panel
Xcellence "E "Series. Ver1.3
3= Return (-)
B
F
G
E
C
D
H
I
2
is used.
Des13