General
Functions.
1 = setting scale. 2 = time settings. 3 = temperature settings.
4 = humidity settings. 5 = water level LED. 6 = on. 7 = off.
Main power switch.
A mains switch on the base of the sauna heater can be used to
interrupt the electricity supply to the heater. This switch should be
used if the sauna will not be used for a longer period, such as
several weeks. Note: The memory function must be reset each
time the power has been interrupted.
Temperature setting.
(Unit in ON position)
Press TEMP – the previous temperature setting is displayed.
The numbers indicate a rising temperature scale. Experiment to
find the temperature that suits you best. Begin for example by
setting the temperature at position 4. If you find that you would
prefer a higher or lower temperature, adjust the setting until you
find the ideal bathing temperature for you (usually 70-90°C (158-
194°F) for traditional dry and wet sauna baths, 45-75°C (113-
167°F) for steam saunas and herbal saunas).
Humidity settings.
(Unit in ON position)
Press RH% – the previous humidity setting is displayed. The
numbers indicate a rising scale. Experiment to find the humidity
that suits you best. Begin for example by setting the humidity at
position 4. If you find that you would prefer a higher or lower
humidity, adjust the dial until you find the ideal humidity for you.
Note: The electronic control logics limits the maximum humidity at
given temperatures.
Timer settings.
(Unit in OFF position)
The numbers in this case represent the pre-set time setting (= the
number of hours before the sauna heater automatically switches on).
To set the timer:
Press TIME – to select the desired time, 1–10 hours.
Press ON – the timer is activated and the time LED flashes during
the pre-set time period. The unit will start with the sauna settings
that were last used. Once the sauna heater has been activated, it
remains on for 3 hours, after which it automatically switches off. If
you want to switch it off earlier, just press OFF.
Traditional sauna bathing.
Dry and wet saunas
(70–110°C (158-230°F), 5–30 RH%)
Press ON – only the sauna LED should be lit. The memory
function automatically sets the previous temperature and humidity
(if any).
Press TEMP – if you want to change the pre-set temperature.
The built-in timer automatically switches the sauna heater off after
3 hours. If you want to switch it off earlier, just press OFF. To
extend the bathing time, press ON – only the sauna LED should be
lit.
8
5
4
CC 20
6
3
If you want steam production at traditional sauna
bathing:
Press RH% – if you want to change the humidity setting. Setting 1
on the humidity scale = no steam production.
Adding water – fill until the water level LED shines steadily (a
buzzer will sound – approx. 8.0 litres (14 pts)). Use regular
drinking water. Steam production will cease when the water level
becomes too low and the level LED starts flashing (a pulsating
buzz sounds).
The electronic control logics will not begin the steam production
until the selected bathing temperature is reached.
The electronic control logics automatically adjusts the humidity to
given temperatures.
Steam Sauna (Tylarium).
(45-70 °C (113-158 °F), 20-65 RH%)
Press ON – until the steam and sauna LEDs glow steadily. The
memory function automatically uses the previous settings for
temperature and humidity.
Press TEMP – if you want to change the temperature setting.
(Setting 1 produces steam only).
Press RH% – if you want to change the humidity setting.
Adding water – fill until the water level LED shines steadily
(a buzzer will sound – approx. 8 litres (14pts)). Use regular
drinking water. Steam production will cease when the water level
becomes too low and the level LED starts flashing (a pulsating
buzz sounds).
The built-in timer automatically switches the heater off after
3 hours, and the automatic drying process is activated. The steam
and sauna LEDs flash, even if you manually pressed OFF.
The drying cycle lasts for about 20 minutes, after which the unit
switches off compleely. If you do not want to activate the drying
process, press OFF again. but if you prefer to switch the heater on
immediately after bathing time before the drying process
commences, press ON – the steam and sauna LEDs will glow
steadily.
To extend the bathing time after the heater has switched to the
drying process (in other words, when both LEDs are flashing), first
press OFF and then ON. Both LEDs should then shine with a
steady light.
Steam production only.
Choose settings according to above, then push TEMP – and
select setting 1 on the temperature scale.
Important!
• If the sauna has a window in the door or wall, treat the entire
lower moulding with boat varnish and seal the joint between the
glass and the moulding with a water-resistant silicone sealant.
This prevents any condensation on the glass from seeping into
the joint.
• Sauna benches, decorative edging and back supports should be
oiled on both sides with Tylö sauna oil.
• Never scatter sauna fragrance in the water inlet (A, Fig. 15) or in
the herb bowl (B, Fig. 15). This will cause a heavy foam build-up
and may trigger the temperature limit control (L, Fig. 4). Empty
the reservoir and rinse it clean of the fragrance, and then reset
the temperature limit control.
• Fill the water inlet with drinking water (A, Fig. 15), until the water
level LED shines steadily (a buzzer will sound – if you keep
filling, the water will overflow). Steam production will cease when
the water level becomes too low and the lever LED starts
flashing (a pulsating buzz sounds). If you want more steam, add
more water, preferably hot. 1.0 litre (1.8 pts) of water is enough
for approximately 20 minutes of steam production.
• To prevent a build-up of calcium deposits, empty the reservoir
after each sauna bath. Note: The water is HOT!
Disconnect the hose (M, Fig. 4), hold it up high and remove the
plug. Lower the hose over a suitable vessel and empty the
remaining water.
• De-scale the reservoir regularly with Tylö Solvent de-scaling agent.
Switch on the heater (max humidity, min temperature) and let it
run until the water in the tank begins to boil. Switch of the heater
and wait for approximately 5 minutes Mix one bag (2.8 oz) with 4
quarts of water, pour it into the water inlet (A, Fig. 15). Leave the