Safety
Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal pres-
sures.
Installation
Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The drain valve must only be used as intended. It is not
allowed to attach other objects to the drain valve, for
example a semi-pedestal.
• If the instantaneous water heater causes problems or
if you wish to increase the water flow, the EcoSmart
(flow limiter) located behind the aerator can be
removed.
Technical
Data
This
mixer
series-produced
with
EcoSmart
limiter)
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The aerator is not equal to DIN EN 246
The product is exclusively designed for drinking water!
4
English
®
(flow
®
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 70°C
65°C
max. 70°C / 4 min
Assembly
see
page
32
Symbol
description
Do not use silicone containing acetic acid!
i
Installation
example
(see page 31)
Operation
(see page 36)
Hansgrohe recommends not to use as drink-
ing water the first half liter of water drawn
in the morning or after a prolonged period
of non-use.
Dimensions
(see page 37)
Flow
diagram
(see page 37)
with EcoSmart
without EcoSmart
Spare
parts
(see page 38)
XXX
=
Colors
000 = chrome plated
820 = brushed nickel
Special
accessories
(order as an
extra)
special tool #58085000
(see page 34)
Installation putty (see page 34)
Hose kit #38959000
(see page 38)
Cleaning
(see enclosed brochure)
Test
certificate
(see page 40)
®
®