Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 32
At the Gun Cleaner
1. Remove the Gun Cleaner's front cover. Remove the suction hoses with their plugs from the pumps, as well as the black ø6 mm
suction hose for manual cleaning (see Picture 1).
2. Place the Docking Unit on the right side of the Gun Cleaner so that the "DRESTER RDX" label is facing the front.
Run the Docking Unit's short hoses (black and white) forward between the Gun Cleaner's stand and the wash basin (see
Picture 2).
3. Run the Docking Unit's long hoses (black and white) backwards in the corresponding manner (see Picture 3).
4. Connect the Docking Unit's short hoses to the Gun Cleaner's pumps (see Picture 4):
The black hose to the lower pump.
The white hose to the upper pump.
5. Cut off about 200 mm from the Gun Cleaner´s solvent return hose from the wash basin, then insert it in the Docking Unit (see
Picture 5).
6. Insert the suction hose (black, ø 6 mm enclosed in a bag) for manual cleaning through the centre plug of the Docking Unit.
The other end is then connected to the coupling on the side of the wash basin (see Picture 6).
7. Fit the maximum level indicator hose (transparent, ø6 mm) onto the brass tube (see Picture 7).
8. Fit the two gas return hoses (transparent, ø6 mm) onto the brass tubes (see Picture 8).
9. Connect the grounding cable (see Picture 9).
10. Cut the black ø8 mm hose (coming from the safety valve's middle fitting on the side of the wash basin) where the arrow
indicates (see Picture 10).
11. Fit the control valve onto the hose (see Picture 11). Place the yellow hose alongside the transfer hoses.
12. Connect the black hose from the Docking Unit's pumps to the upper outlet fitting on the left side of the control valve (see
Picture 12).
Fit the Docking Unit's cover and the Gun Cleaner's front cover. The installation at the Gun Cleaner is now completed.
At the Recycler
1. Picture 13 shows the enclosed valve components.
2. Fit the console with the control valve on the right side of the Recycler (see Picture 14).
3. Remove the plug from the solvent inlet and fit the 90º-coupling. If necessary, use the enclosed bushing (1/4 -3/8").
Then fit the brass connector (see Picture 15).
4. Connect the solvent hose (black with protective metal hose, see Picture 16).
5. Connect the distillate hose (see Picture 17).
6. Picture 18 shows the distillate container with level indicator.
7. Place the distillate container underneath the Recycler and insert the distillate hose (see Picture 19).
8. Connect the suction hose for clean solvent (white with protective metal hose, see Picture 20).
9. Trim the hoses from the Gun Cleaner to the correct length (see Picture 21).
10. Connect the hoses from the Gun Cleaner. Note the colour-coding: white for clean solvent, and black for
contaminated solvent (see Picture 22).
11. Connect the yellow air line (see Picture 23).
12. Connect clean, dry compressed air of 3–10 bar to the control valve inlet (see Picture 24).
13. Tie the hoses together using the supplied cable ties (see Picture 25).
The installation at the Recycler is now completed and the "DRESTER DYNAMIC TRIPLE 8000" is ready to be taken into use
(see Picture 26).
Warning:
Make sure that all parts of the system are grounded (machines and drums).

INSTALLATION

(see illustration enclosure 11142)
4

Publicidad

Tabla de contenido
loading

Tabla de contenido