ENGLISH
The compensation curve for heating maintains a theoretical temper-
ature of 20°C indoors, when the external temperature is between
+20°C and -20°C. The choice of the curve depends on the minimum
external temperature envisaged (and therefore on the geographical
location), and on the delivery temperature envisaged (and therefore
on the type of system). It is carefully calculated by the installer on the
basis of the following formula:
Design delivery temp - Tshift
KT =
20 - Design min outside temp
Tshift = 30 °C standard system
25 °C floor system
If the calculation produces an intermediate value between two
curves, you are advised to choose the compensation curve nearest
the value obtained.
Example: if the value obtained from the calculation is 1.3, this is be-
tween curve 1.0 and curve 1.5. Choose the nearest curve, i.e. 1.5.
Selection of the KT must be made by acting on the P3 trimmer on the
card (see multi-wire electrical diagram).
To access P3:
1.
remove the shell,
2.
turn the instrument panel upside down
- remove the electrical parts inspection cover, undoing the 2 fixing
screws
Live electrical parts (230 Vac).
The following KT values can be set:
- standard system: 1.0 - 1.5 - 2.0 - 2.5 - 3.0
- floor system: 0.2 - 0.4 - 0.6 - 0.8
and they will be shown on the display for about 3 seconds after the
P3 trimmer is turned,
Design minimum
Location
outside temperature
Turin
Alexandria
Asti
Cuneo
Alta valle Cuneese
Novara
Vercelli
Aosta
Valle d'Aosta
Alta valle Aosta
Genoa
Imperia
La Spezia
Savona
Milan
Bergamo
Brescia
Como
Como Province
Cremona
Mantua
Pavia
Sondrio
Alta Valtellina
Varese
Trento
Bolzano
Venice
Belluno
Padua
Rovigo
Treviso
Verona
Verona lake area
Verona mountain area
Based on experience, the installer can still choose different curves.
12
Location
-8
Vicenza
-8
Vicenza highlands
-8
Trieste
-10
Gorizia
-15
Pordenone
-5
Udine
-7
Lower Carnia
-10
Upper Carnia
-15
Tarvisio
-20
Bologna
0
Ferrara
0
Forlì
0
Modena
0
Parma
-5
Piacenza
-5
Piacenza Province
-7
Reggio Emilia
-5
Ancona
-7
Macerata
-5
Pesaro
-5
Florence
-5
Arezzo
-10
Grosseto
-15
Livorno
-5
Lucca
-12
Massa
-15
Carrara
-5
Pisa
-10
Siena
-5
Perugia
-5
Terni
-5
Rome
-5
Frosinone
-3
Latina
-10
Rieti
Design minimum
outside temperature
-5
Viterbo
-10
Naples
-5
Avellino
-5
Benevento
-5
Caserta
-5
Salerno
-7
L'Aquila
-10
Chieti
-15
Pescara
-5
Teramo
-5
Campobasso
-5
Bari
-5
Brindisi
-5
Foggia
-5
Lecce
-7
Taranto
-5
Potenza
-2
Matera
-2
Reggio Calabria
-2
Catanzaro
0
Cosenza
0
Palermo
0
Agrigento
0
Caltanissetta
0
Catania
0
Enna
0
Messina
0
Ragusa
-2
Syracuse
-2
Trapani
-2
Cagliari
0
Nuoro
0
Sassari
2
-3
Design minimum
Location
outside temperature
-2
2
-2
-2
0
2
-5
0
2
-5
-4
0
0
0
0
0
-3
-2
3
-2
-3
5
3
0
5
-3
5
0
5
5
3
0
2