Safety Notes

6 Gloves should be worn during installation to prevent
crushing and cutting injuries.
6 The shower system may only be used for bathing,
hygienic and body cleansing purposes.
6 The hot and cold supplies must be of equal
pressures.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The fitting must be installed, flushed and tested after
the valid norms.
• If the instantaneous water heater causes problems or
if you wish to increase the water flow, the EcoSmart
(flow limiter) located behind the aerator can be
removed.

Technical Data

This mixer series-produced with EcoSmart
limiter)
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
• Hansgrohe mixers can be used together with
hydraulically and thermically controlled continuous
flow heaters if the flow pressure is at least 0,15 MPa.
• The product is exclusively designed for drinking water!
4
English
®
(flow
®
max. 1 MPa
0,1 – 0,5 MPa
1,6 MPa
max. 80°C
65°C
max. 70°C / 4 min
Assembly see page 31
Symbol description
Adjustment
To adjust the hot water limiter on single lever
mixers, please see page 34. Using a hot
water limiter in connection with a continuous
flow water heater is not recommended.
Do not use silicone containing acetic acid!
Dimensions (see page 35)

Flow diagram

(see page 36)
with EcoSmart
without EcoSmart
Spare parts (see page 37)
Special accessories (order as an
extra)
special tool #58085000
seal #98996000
Installation putty
Operation (see page 38)
• Hansgrohe recommends not to use
as drinking water the first half liter of
water drawn in the morning or after a
prolonged period of non-use.
• After periods of prolonged non-use, but
at least every third day, the fittings must
be opened with the handle in hot and
cold position to prevent stagnation in the
connecting lines. Let the water run until the
water temperature is constant.
Cleaning
see enclosed brochure.
Test certificate (see page 40)
®
®