Broan ULTRA Pro RB80L1 Guia De Instalacion página 5

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Page 5
New Construction Installation
5
Connect Wires and Install Knockout Plate
• Run 120VAC electrical wiring to the installation location.
• Use proper UL-approved connectors to secure wiring to the Knockout Plate provided in Parts Bag.
• Connect wires as shown in wiring diagram.
LIGHT
SWITCH
FAN
SWITCH
BLK
LINE
WHT
IN
GRD
BLK
WHT
LINE
IN
GRD
Attach cable clamps to
1
Knockout Plate. Knockout
Plate mounts to outside of
Housing and may be
oriented as desired.
2
Connect wires
LIGHT WITH ON/OFF SWITCH
RED
BLK
WHT
GRD
SWITCH BOX
LIGHT WITH DIMMER SWITCH
DIMMER
FAN
SWITCH
SWITCH
SWITCH BOX
BLU
WHT
LIGHT
RED
BLK
WHT
FAN
UNIT
RED
BLU
LIGHT
RED
BLK
BLK
FAN
WHT
GRD
UNIT
RB80L1
RB110L1 Installation Guide
n
3
4
Screw from
Parts Bag
WHT
WHT

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ultra pro rb110l1

Tabla de contenido