Instruction Manual; General Safety Instructions; Technical Data; Commissioning, Operation - REMS Push Instrucciones De Servicio

Ocultar thumbs Ver también para Push:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 11
eng
Translation of the Original Instruction Manual
Fig. 1 – 2
1 High-pressure hose
2 Return valve
3 Tank/INOX tank
4 Pump lever
5 Pressure gauge
6 Suction filter
General safety instructions
CAUTION
Read all the safety notes, instructions, illustrations and technical data which
come with this device. Failure to heed the following instructions can lead to severe
injuries.
Keep all safety notes and instructions for the future.
Only use the tool for the intended purpose and under observance of the general
safety and accident prevention rules.
a) Keep your workplace tidy. Untidiness in the work area can cause accidents.
b) Use the right tool. Do not use weak machines for heavy work. Do not use the
tool for a purpose for which it is not intended.
c) Check the tool for damage. Slightly damaged parts must be checked carefully
for perfect and proper functioning every time before using the tool. Check whether
the moving parts work perfectly and do not jam or are damaged. All parts must
be mounted correctly and meet all conditions to ensure perfect operation of the
tool. Damaged parts must be properly repaired or changed by a recognised
specialist unless specified otherwise in the operating manual.
d) Be careful. Pay attention to what you are doing. Work sensibly.
e) Do not overload your tool. You can work better and safer in the specified work
range. Renew worn tools in time.
f) Wear suitable work clothing. Do not wear loose clothing or jewellery as these
can get caught in moving parts. Rubber gloves and non-slip shoes are recom-
mended for working outdoors. Wear a hair net over long hair.
g) Use personal safety equipment. Wear safety glasses. Wear protective gloves.
h) Avoid abnormal body posture. Make sure that you have a firm footing and
keep your balance at all times.
i) Take good care of your tools. Keep the tools clean to work better and safer.
Follow the maintenance regulations and instructions. Keep handles dry and free
from grease and oil.
j) Take ambient influences into account. Do not expose your tools to rain. Provide
good lighting.
k) Keep other persons away. Do not let other persons touch your tools. Keep other
persons and especially children away from your work area.
l) Only use genuine accessories and genuine spare parts for your own safety
for the intended function of the tool. The use of other insertion tools and
accessories can cause you injury.
m) Have your tool repaired by a qualified specialist. This tool satisfies the perti-
nent safety regulations. Repairs may only be done by a recognised specialist or
instructed person with the use of genuine spare parts, otherwise the user could
have an accident. All unauthorised modifications to the tool are prohibited for
safety reasons.
Safety instructions for the hand pressure testing pump
CAUTION
Read all the safety notes, instructions, illustrations and technical data which
come with this device. Failure to heed the following instructions can lead to severe
injuries.
Keep all safety notes and instructions for the future.
● Do not use the device if it is damaged. There is a danger of accident.
● The device develops very high pressures of up to 6 MPa (60 bar, 870 psi).
So be very careful. Keep third parties away from the work area when working
with the device.
● Examine the high-pressure hoses for damage every time before using.
Damaged high-pressure hoses can burst and cause injury.
● Only use original high-pressure hoses, fittings and couplings for the device.
This ensures that the safety of the device is maintained.
● Place the device horizontally on a level surface for operation. If operated on
an inclined, uneven surface, liquid can escape from the tank (3) or the device
can tip over.
● Do not suck up inflammable or explosive liquids, for example petrol, oil,
alcohol, solvent, with the device. The fumes or liquids can ignite or explode.
● Protect the device against frost. The device could be damaged.
● Do not overload the device. Overloading can damage the device. There is a
risk of injury.
● Children and persons who, due to their physical, sensory or mental abilities
or lack of experience and knowledge are unable to operate the device safely
may not use this device without supervision or instruction by a responsible
person. Otherwise there is a risk of operating errors and injuries.
● Only allow trained persons to use the device. Apprentices may only operate
the device when they are older than 16, when this is necessary for their training
and under the supervision of a trained operative.
A Hand pressure testing pump
B Installed lines
C Connecting line
D Pressure gauge
E Shut-off valve
F Shut-off valve upstream of installed
system
Explanation of symbols
CAUTION
Danger with a low degree of risk which could result in minor
injury (reversible) if not heeded.
NOTICE
Material damage, no safety note! No danger of injury.
Read the operating manual before starting
Environmentally friendly disposal
CE conformity mark

1. Technical Data

Use for the intended purpose
CAUTION
REMS Push and REMS Push INOX are designed for pressure and leak testing of
pipe systems and vessels. All other uses are not for the intended purpose and are
therefore prohibited.
NOTICE
The respective national safety provisions, rules and regulations valid for the
application site must be considered and observed for proper use.
1.1. Scope of Supply
Hand pressure testing pump, high-pressure hose, instruction manual
1.2. Article numbers
REMS Push
REMS Push INOX
Connection piece with pressure gauge and shut-off valve
Fine scaled pressure gauge
REMS CleanM
1.3. Work area/dimensions/weight
Capacity of the tank
Test and pressure range
pH value of the liquids
Temperature of the liquids
Viscosity of the liquids
Dimensions REMS Push, REMS Push INOX
Weight REMS Push, REMS Push INOX
Hose connection
2. Commissioning/Operation
CAUTION
Medium under pressure can escape in case of leaks. Protect the area from
unauthorised access during pressure testing.
The hand pressure testing pump (A) is used for pressure and leak testing of
pipe systems (B), observe EN 806-4 standard and national regulations. To do
so, attach the connecting line (C) with pressure gauge (D) with specified scale
and also the shut-off valve (E) to the installed system. Close the shut-off valve
(E) and fill the system. Connect the high-pressure hose (1) of the hand pressure
testing pump to the system being tested (hose connection ½"). Open the return
valve (2), open the shut-off valve (E) and fill the tank (3). Close the return valve.
Bleed the installed system. Close the shut-off valve upstream of the installed
system (F). Set the specified/required test pressure by pumping several times
with the pump lever (4). In the case of major differences between the ambient
temperature and the water temperature a waiting period until these temperatures
are balanced is necessary. Close the shut-off valve (E) on the installed system.
Comply with the testing time as specified. After completion of the pressure test,
open the return valve (2). Remove the high-pressure hose from the installed
system.
Attention: Before connecting the high-pressure hose (1), make sure that
the pressure has been relieved completely. Note the pressure on the
pressure gauge (5).
NOTICE
Do not use the hand pressure testing pump without the suction filter (6).
3. Maintenance
3.1. Maintenance
Grease the pump piston from time to time. Check high-pressure hose (1) and
seals for damage before every use. Do not use a damaged high-pressure hose
and damaged seals. Clean the suction filter (6) regularly. Channge a damaged
suction filter. Clean plastic parts (e.g. housing, high-pressure hose) only with
REMS CleanM machine cleaner (Art. No. 140119) or a mild soap and a damp
cloth. Do not use household cleaners. These often contain chemicals which
can damage the plastic parts. Never use petrol, turpentine, thinner or similar
products for cleaning.
3.2. Inspection/Repair
This work may only be performed by qualified personnel.
eng
115000
115001
115110
115045
140119
12 l
p ≤ 6 MPa / 60 bar / 870 psi
7 – 12
≤ 60°C
≤ 1.5 mPa s
500 × 190 × 280 mm
6.9 kg
½"
5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Push inox

Tabla de contenido