Technical Data

Solder fume extraction
Dimensions L x W x H
Weight
Mains supply voltage
Electrical power rating
Fuse
Maximum vacuum
Maximum quantity
supplied
Noise emission level
Pre filter Stage 1
Combined filter
Stage 2; 3
RS232 port
USB port
Warranty
Claims by the buyer for physical defects are time-barred after a period of one year from delivery to the
buyer. This does not apply to claims by the buyer for indemnification in accordance with §§ 478, 479
BGB (German Federal Law Gazette).
We shall only be liable for claims arising from a warranty furnished by us if the quality or durability warranty
has been furnished by use in writing and using the term „Warranty".
The warranty shall be void if damage is due to improper use and if the device has been tampered with by
unauthorised persons.
Subject to technical alterations and amendments.
For more information please visit www.weller-tools.com.
Disposal
Do not dispose of electric tools together with household waste material! In observance
of European Directive 2002/96/EC on waste electrical and electronic equipment and its
implementation in accordance with national law, electric tools that have reached the end
of their life must be collected separately and returned to an environmentally compatible
recycling facility.
Contaminated filters must be treated as special waste.
Dispose of replaced equipment parts, filters or old devices in accordance with the rules
and regulations applicable in your country.
Zero Smog 4V
320 x 320 x 395 mm
19 kg
T0053660699:
230 V / 50 Hz
T0053660299:
120 V / 60 Hz
275 VA
T1, 6A
2.700 Pa
230 m³/h
48 dB(A)
pre filter mat class F7
Combined E12 high efficiency submicron filter (99.95 % particle separati-
on upto 0.12 μm)
and wide band gas filter (50 % activated carbon, 50 % Puratex)
All system functions can be operated and remotely monitored via the
RS232 port.
The USB port can be used to load firmware updates, run efficiency tests
and log data.
Do not leave the USB medium inserted for longer than 2 minutes. After
this time expires, the USB module will switch off automatically.
Zero Smog 6V
450 x 450 x 650 mm
40 kg
T0053666699:
230 V / 50 Hz
T0053666299:
120 V / 60 Hz
460 VA
T3, 15A
2.800 Pa
615 m³/h
51 dB(A)
Zero Smog 20T
450 x 450 x 695 mm
45 kg
T0053670699:
230 V / 50 Hz
T0053670299:
120 V / 60 Hz
530 VA
T3, 15A
10.000 Pa
100 m
/h
3
51 dB(A)
17