See Figure 7.
n
Rotate drain valve right to open.
n
n
n
n
WARNING:
Unplug the air compressor and release all air from
the tank before servicing. Failure to depressurize tank
before attempting to remove valve may cause serious
personal injury.
n
Rotate drain valve left until tightly closed.
See Figure 8.
n
n
n
n
OPERATION
WARNING:
If air leaks after the ring has been released, or if the
valve is stuck and cannot be actuated by the ring,
Do Not use the air compressor until the safety valve
has been replaced. Use of the air compressor in this
condition could result in serious personal injury.
END OF OPERATION/STORAGE
Turn ON/OFF power switch to the OFF position.
Unplug power cord from wall outlet and wrap around
handle area to prevent damage when not in use.
Wearing safety glasses drain tank of air by pulling the
ring on the safety valve. Use other hand to deflect fast
moving air from being directed toward your face.
Drain tank of condensation by opening drain valve on
bottom of tank. Tank pressure should be below 10 psi
when draining tank.
Air hose should be disconnected from compressor and
hung open ends down to allow any moisture to drain.
Compressor and hose should be stored in a cool, dry
place.
14
DRAIN VALVE
(Rotate drain valve right to open)
Fig. 7
SAFETY
VALVE
Fig. 8