mechanical safety clutch. The motor has electronics for soft start, overload protection and thermal (overheating)
protection.

ELECTRICAL CONNECTION

The network voltage must conform to the voltage indicated on the tool name plate.
Under no circumstances should the tool be used when the power supply cable is damaged. A damaged
cable must be replaced immediately by an authorized Customer Service Center. Do not try to repair the
damaged cable yourself. The use of damaged power cables can lead to an electric shock.
WARNING:
This machine is equipped with a Portable Residual Current Device (PRCD) also known as a Ground Fault
Circuit Interrupter (GFCI). Always use this device whenever using the machine to reduce the risk of
shock hazards. Test and reset the PRCD device before each
use. Press the "Test" button to test. Press the "Reset" button to
energize the circuit.
WARNING!: 110V UK machines are not equipped with a PRCD
portable residual current device or GFCI ground fault circuit
interrupter. The machine must always be used with an isolating
transformer for protection in case an electrical fault should
occur.
Use an RCD in a separate control box with one or more socket
outlets in accordance with EN 60309-2 with the earthing contact position 1 h.
ASSEMBLY
1.
Mount the handle clamp of the side handle onto the gearbox neck. Position the side handle perpendicular
to the main handle. Use the lock screw to tighten the clamp.
2.
Thread the water supply assy. Into the hole in the bottom of gearbox and tighten with a wrench.
LIST OF CONTENTS
Diamond core drilling machine.
Side handle assembly
Water feed assembly
Wrench
OPERATING INSTRUCTIONS
1) MOUNTING THE CORE BIT
CAUTION: Ensure that the threads of the spindle and the core bit match. Attempting to mount
mismatched threads will result in damage to both threads.
The spindle has two types of threads. The outside male thread is 1-1/4inch UNC, the inside female thread is 1/2
inch BSP.
Ensure both the core bit and the machine spindle are clean. Any debris could cause excessive run-out of the
mounted core bit. Excessive run-out can cause premature failure of the core bit and/or a safety hazard.