General; Long Term Storage - Generac XG Professional Serie Manual Del Usuario

Ocultar thumbs Ver también para XG Professional Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Figure 13 – Air Filter
AIR FILTER
3.5 CLEAN SPARK ARRESTOR SCREEN
The engine exhaust muffler has a spark arrestor screen. Inspect
and clean the screen at least once each year (Figure 14). If unit is
used regularly, inspect and clean more often.
If using the generator on any forest-covered, brush-
covered or grass-covered unimproved land, it must
equipped with a spark arrestor. The spark arrestor must
be maintained in good condition by the owner/operator.
Clean and inspect the spark arrestor when the engine is at ambient
temperature as follows:
Loosen the clamp and remove the spark arrestor screen from
the muffler.
Inspect screen and replace if torn, perforated or otherwise
damaged. DO NOT USE a defective screen. If screen is not
damaged, clean it with commercial solvent.
Replace the spark arrestor and secure with the clamp.
Figure 14 – Spark Arrestor Screen
14
Section 3 — Maintenance
Portable Generator System
COVER
ARRESTOR
SCREEN
CLAMP
SPARK
ARRESTOR
SCREEN

3.6 GENERAL

The generator should be started at least once every seven days
and be allowed to run at least 30 minutes. If this cannot be done
and the unit must be stored for more than 30 days, use the
following information as a guide to prepare it for storage.
NEVER store engine with fuel in tank indoors or in
enclosed, poorly ventilated areas where fumes may
reach an open flame, spark or pilot light as on a
furnace, water heater, clothes dryer or other gas
appliance.
Allow unit to cool entirely before storage.

3.7 LONG TERM STORAGE

It is important to prevent gum deposits from forming in essential
fuel system parts such as the carburetor, fuel hose or tank during
storage. To avoid engine problems, the fuel system should be
emptied before storage of 30 days or longer, as follows:
Remove all gasoline from the fuel tank.
Drain fuel into approved container outdoors, away from
open flame. Be sure engine is cool. Do not smoke in the
vicinity or light a cigarette.
Start and run engine until engine stops from lack of fuel.
Allow the engine to cool, then drain oil from crankcase. Refill
with recommended grade.
Remove spark plug and pour about 1/2 ounce (15 ml) of engine
oil into the cylinder. Cover spark plug hole with rag. Pull the
recoil starter a couple times to lubricate the piston rings and
cylinder bore.
Avoid spray from spark plug hole when cranking
engine.
Install and tighten spark plug. Do not connect the spark plug
wire.
Clean the generator outer surfaces. Check that cooling air slots
and openings on generator are open and unobstructed.
Store the unit in a clean, dry place.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Professional xg7000eProfessional xg8000e005845-0005847-0

Tabla de contenido