- Only use grinding tools which
bear information about the manu-
facturer, type of binding, dimen-
sion and permitted number of
revolutions.
- Only use grinding discs where
the printed rotational speed is at
least as high as what has been
specified on the name plate of
the device.
- Do not use broken, cracked or oth-
erwise damaged grinding discs.
- Never operate the device without
the visual protection disc.
- Always inspect the grinding disc
before starting the device:
Check the distance between the
spark protection and grinding
disc as well as workpiece support
and grinding disc (distance maxi-
mum 2 mm).
- The grinding disc must be re-
placed once the spark protection
and workpiece support on the
grinding disc do not have dis-
tance of max. 2 mm.
- Switch on the equipment only
when it is safely installed on the
work surface.
Keep your hands away from
the grinding disc when the
device is in operation. Injury
hazard!
Switching on and off
Ensure that the mains voltage
matches the specifications on the
rating plate.
Connect the equipment to the mains.
1. To switch on, press the "I" On switch
and the device starts up (see
2. To switch off, press the "0" off switch
and the device switches off (see
14b).
After switching on the device, wait until the
device has reached its max. speed. Only
then must you start with the grinding.
The disc will continue to
run after the equipment is
switched off. There is a risk of
injury.
Test run:
Before starting work and after each change
of grinding disc, carry out a test run of at
least 60 seconds with no load. Switch off
the equipment immediately if the disc runs
lumpy, substantial vibrations occur, or ab-
normal noises are generated.
Grinding with the grinding
disc
The arrow on the protective hood
(
5) shows the direction of rota-
tion of the grinding disc.
•
Place the workpiece on the workpiece
support (
11) and slowly bring it to
its desired angle on the grinding disc
(
10).
•
Move the workpiece slightly from side
to side in order to achieve an optimal
grinding result. This way, the grinding
disc is worn uniformly. Occasionally,
allow the workpiece to cool down.
•
The magnifying glass set into the spark
protection window (1) helps you to
work accurately.
GB
MT
14a).
59