5.6. Alarms
HIGH SALT LEVEL
If too much salt has been added, the production level will automatically fall beneath the selected level. The "HIGH SALT" [7] light
will stay on. In this case, empty part of the pool (10%, for instance) and add fresh water to reduce the salt concentration.
LOW SALT LEVEL
If the level of salt in the swimming pools water were below the recommended level, the power supply may not reach the level of
output selected. The "LOW SALT" [6] light will stay on. It is possible that the system indicates salt levels below the real ones if the
water temperature is less than 20ºC or if the electrode package has reached the end of its lifetime. In this case, determine the level
of salt in the water and add the amount of salt needed The type of common salt (NaCl) indicated for salt electrolysis should have no
additives (anti-clogging agents, iodides) and should be suitable for human consumption. To know the exact level of salt we
recommend the use of a portable salinity-temperature meter.
WATER LEVEL IN CELL/FLOW DETECTOR (GAS)
If an air or gas bubble forms at any time at the top of the electrolysis cell and the FLOW DETECTOR is not submerged, the system
will automatically switch off production, with the "FLOW" [12] light blinking and "FLO" displayed on the system information screen
[11]. The system automatically resets when water flows through the cell again or the bubble disappears.
1. Submerged gas detector. System running.
EXTERNAL FLOW DETECTOR (FLOW SWITCH)
During the system configuration process (point 5.2), the input for the external flow switch is activated (factory-programmed default
value), the system will automatically switch off production, with the "FLOW" [12] light blinking, and "FLO" displayed on the system
information screen [11]. The system automatically resets whenever water starts to flow through the flow switch again.
High salt level
Fig. 26
Fig. 27
19
Low salt level
2. Gas detected. System off.