The individual feed lines to
each Colorfalls should be 1½"
PVC. If using one pump to feed
multiple Colorfalls, the main
feed line should be 2" or larger.
The main feed line should be
run horizontally along the back
of the wall with vertical 1½" feed
lines branching off to each
Colorfalls (Figure 3).
Operation
Technical Data (Control Module)
Working Temperature:
0°F -140°F (-20°C - 60°C)
Output: 3 circuits (R/G/B)
Installation Requirements
1. The Control Module is weather-resistant with an IP54 rating. Do not submerse it or
expose it to heavy rainfall. It must be mounted off the ground close to the power source.
Failure to do so will void the warranty.
2. Remove the red protective cap from the top of the control module and install the
antenna. Thread the black antenna on until snug, making sure it seals against the gasket.
3. Install the control box in a well ventilated area to ensure that the module operates in
within its working temperature specified above.
4. Verify that the control module input voltage is 12 volt AC. We recommend that you use
the transformer provided with this unit.
5. Ensure that all cable connections are secure.
6. Do not connect the power before the cord connections are finished.
7. Do not cut or alter the cord between the Colorfalls and the Control Module.
8. The remote control requires three (2) AAA batteries (not included). Do not touch the face
of the remote while installing batteries.
Connecting the Light Bar
The Colorfalls light bar will not operate if plugs are aligned incorrectly. The six pronged
connectors have raised arrows that indicate proper alignment. Follow the connecting chart
below to connect all cables. Ensure that the unit
is not plugged in while connecting.
LED Light Strip
4
1½"
Figure 3
Input Power: AC12V
Output Power: DC12V, 80 watts max
Output Current: 2A /circuit
1½"
Control Module
2" Feed
Lines
Transformer