Connecting the water sensor
13.10 Connect the power source (A).
13.11 The electronic module (C) initialises for approx. 15 seconds.
☞
Wait until the flashing stops, one LED is always flashing.
13.12 Connect the "water" sensor (a).
☞
Wait until the "water" sensor (a) stops flashing.
13.13 Disconnect the power source for at least 2 seconds (B).
13.14 Connect the power source (A).
13.15 The electronic module (C) initialises for approx. 15 seconds.
13.16 Allow your hand to approach the "water" sensor (a) and then hold your hand in front of it
until the solenoid valve is actuated and water flows from the outlet.
13.17 The washbasin (Z) is not part of the scope of delivery (siehe
Connecting the hand dryer sensor (if included)
13.18 Connect the "hand dryer" sensor (d).
☞
Wait until the "hand dryer" sensor (d) stops flashing.
13.19 Disconnect the power source for at least 2 seconds (B).
13.20 Connect the power source (A).
13.21 The electronic module (C) initialises for approx. 15 seconds.
13.22 Allow your hand to approach the "hand dryer" sensor (d) and then hold your hand in
front of it until air flows out from the outlet.
14. Resetting the Sensor
☞
When voltage is applied without sensors connected, sensors previously logged in to the
electronic module are logged back out again.
14.1 Disconnect the power source (siehe
14.2 Disconnect the line connections to all sensors.
14.3 Connect the power source (siehe
☞
Important!
Wait at least 2 minutes.
14.4 Connect the sensors (siehe
Kapitel
13.11).
Kapitel
13.8).
Kapitel
13.).
Kapitel
18.).