- English -
3. Remove the four screws and take off the
pump casing
4. Pull out the impeller unit and replace if
necessary.
• Use a wide-blade screwdriver to carefully
lever out the impeller unit if necessary.
5. Reassemble the unit in the reverse order.
Storage/Winterization
The unit is frost resistant to minus -4°F (20 °C). Should you store the unit outside of the pond, clean it thoroughly with a soft
brush and water, check it for damage, then store immersed in water or filled with water. Do not immerse the power plug in
water!
Wear parts
• Impeller unit
• Bearing in the motor block
Repair
Repair is not possible in the following cases. The pump has to be replaced.
• If there is no replacement part approved by OASE for a defective component.
• If an electric cable permanently connected to the pump becomes damaged or is shortened.
Disposal
Do not dispose of this unit with domestic waste! Disable the unit beforehand by cutting off the cables. Further
information about the recycling of this product can be obtained from your local municipal authority.
Spare parts
The use of original parts from OASE ensures continued safe and reliable operation of the unit.
Please visit our website for spare parts drawings and spare parts. www.oase-livingwater.com
Questions, problems, missing parts?
Before returning to your retailer, call us at 1-866-627-3435, 8 a.m.-6 p.m., EST, Monday-Friday, or email
us at customercare@oase-livingwater.com. Or visit our website at www.oase-livingwater.com