Idiomas disponibles

the mounting
bolt should be inserted into the slot with its head down
and threaded shank pointed upward (ill. 1).
2) Drill four 11/64" holes on the floor at
the location shown in the Unifit Rough-
In installation instructions found in
the Rough-In box (see Illustration 2).
(5/16" holes are for concrete / tile floor
anchors).
3) Turn the PVC outlet connection upside
down. Firmly press a new wax seal onto
the circular recess around the outlet
opening. Turn the outlet connection
upright and lower it into position over
the closet flange. With the unit properly
aligned, press down firmly to set the
wax seal (see Illustration 3).
CA UTION: Do not move the outlet
connection after the wax seal is set.
4) Insert the washers and thread nuts onto
the mounting bolts and hand-tighten
(see Illustration 4). Then tighten bolts
an additional ½ turn. Secure the back
side of the outlet connection to the
floor using the 4 screws and washers.
Insert the T-bolts into the slots with the
head down and threaded shank pointed
upward.
NO TE: Do not remove the white tie-
wrap from rubber sleeve. Level the
PVC outlet. Do not use excessive
force.

INSTALLATION PROCEDURE

Install Mounting Bolts
Install Outlet Connection
4
Ill. 1
The
Ill. 2
Finished Wall
B
2"
A
Ill. 3
Ill. 4
T-Bolts
Slot
Floor
Closet Flange
C/L
C
Wax Seal
Nut
Bolt