For power cord installations only (see the next step if using conduit),
assemble the strain relief in the hole. Insert the power cord through
the strain relief and tighten. Allow enough slack to easily attach the
cord terminals to the terminal block. If tabs are present at the end o
the winged strain relief, they can be removed for better fit.
NOTE: Do not install the power cord without a strain relief. The strain
relief bracket MUST be installed before reinstalling the rear range
wiring cover.
Strain relief
Power cord
2
3-WIRE INSTALLATION (GROUND IS THROUGH THE NEUTRAL WIRE)
WARNING
Shock Hazard
The neutral wire and ground strap must be connected as shown
below for the range to be properly grounded. Do not remove the
ground strap. Failure follow this instruction may result in potential
shock hazard.
WARNING
Fire hazard
Terminal block screws must be securely tightened. Failure to do
so may result in potential fire hazard.
FOR POWER CORD INSTALLATION
A. Remove the 3 lower screws from the terminal block. Do not loosen the upper screws.
B. Do not cut or remove the ground strap.
C. Insert the 3 screws through each power cord terminal ring and back into the terminal block. Be certain the white wire is in the center. Securely tighten
each screw (35 to 50 in-lbs).
FOR CONDUIT INSTALLATION
A. Loosen the 3 lower screws on the terminal block. Do not loosen the upper screws.
B. Do not cut or remove the ground strap.
C. Insert the bare wire tip (insulation stripped 5/8") into the bottom terminal block openings. Be certain the white wire is in the center. On certain models, the
wire must be inserted through an opening in the ground strap. Securely tighten each screw onto each wire (35 to 50 in-lbs).
D. Reinstall terminal block cover.
NOTE: For conduit wires using copper wires, the allowable gauge of the individual wires is 6-8 AWG.
NOTE: Aluminum building wire may be used but it mustbe rated for the correct amperage and voltage. For conduit wires using aluminum wires, the
allowable gauge of the individual wires is 4-8 AWG.
3
4-WIRE INSTALLATION (SEPARATE GROUND WIRE)
WARNING
The neutral wire of the supply circuit must be connected to the neutral terminal located in the lower center of the terminal block.
The power leads must be connected to the lower left and the lower right terminals of the terminal block. The grounding lead must be connected to the
frame of the range with the ground plate and the green ground screw.
FOR POWER CORD INSTALLATION
A. Remove the 3 lower screws from the terminal block. Do not loosen the upper screws.
B. Remove the ground screw and ground plate and retain them.
C. Cut the ground strap below the terminal block and discard the lower section.
D. Insert the ground screw through the ground plate (remove earlier) and back into the range frame. Tighten securely, but do not over-tighten (15 to 20
in-lbs).
E. Insert the terminal screws through each power cord terminal ring and back into the terminal block. Be certain the white wire is the center. Securely
tighten each screw (35 to 50 in-lbs).
F. Reinstall terminal block cover.
FOR CONDUIT INSTALLATION
A. Remove the 3 lower screws from the terminal block. do not loosen the upper screws.
B. Remove the ground screws and ground plate and retain them.
C. Cut the ground strap below the terminal block and discard the lower section.
D. Insert the bare ground bare wire tip (insulation stripped ⅝") between the range frame and the ground plate (remoived earlier) and secure it in place
with the ground screw. Tighten securely, but do not over-tighten (15 to 20 in-lbs).
INSTALLATION INSTRUCTIONS
Terminal
block
Bracket
C
For 3/4" conduit installations only, purchase a squeeze connector
matching the diameter of your conduit and assemble it in the hole.
Insert the conduit through the squeeze connector and tighten. Allow
enough slack to easily attach the wires to the terminal block.
NOTE: Do not install the conduit without a squeeze connector. The
squeeze connector MUST be installed before reinstalling the rear
terminal block.
Squeeze
connector
Conduit
Power Cord
Terminal block
(appearance
may vary)
Neutral
terminal
Ground
strap
Ground
Red or
plate
Black
Red or
Black
White
Power cord
18
Terminal block
Bracket
Conduit
Terminal
block
Wire
tips
Red or
Black
Red or
Black
White
Conduit