Water Supply; Electrical Installation; Control Panel - Vetus SMTO2 Instrucciones De Instalación Y Manual De Manejo

Inodoros marinos eléctricos
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 18
5.3 Outlet
Reducing piece:
1 Position the reducing piece (F) in the outlet connection.
2 Fix the reducing piece using the hose clamp (E).
 Fit the outlet hose (ø 19 mm).
4 The reducing piece can be fitted in any position so that
the outlet hose can be led to the left, right, up or down as
required.
5 The bent part of the reducing piece can be sawn off in order
to lead the outlet behind the toilet.
1
2
F
E
4
F
For the outlet pipe use a 19 mm internal diameter hose (such as
the 'Vetus impermeable "no smell" sanitary hose').
Fix the outlet with clamps.
Electric marine toilet SMTO2
3
F
F
E
5
E
F

5.4 Water supply

Fit a ball valve with /4" external connection to the supply pipe
and make sure that this will always be accessible.
If there is already a pressurised water system on board the sup-
ply hose can be connected to this system. The pressure must
be at least 1.5 bar; this is the minimum pressure required to
allow the toilet to function properly.
If the water pressure system is less than 1.5 bar or if external
water is to be used then a supply pump with capacity of at least
10 litres/minute (2.2-Imp.Gal/min; 2. US Gal/min) must be fit-
ted in the water supply pipe.
If external water is to be used then this must be properly fil-
tered.
The toilet has a /4" connector.
Connect the flexible water supply hose to the ball valve on the
water supply pipe.

5.5 Electrical installation

Check that the voltage given on the type plate on the motor is
the same as the voltage on board.
Use batteries with sufficient power to guarantee that the toilet
will work correctly.
Connect the power supply as shown in the wiring diagram.
Fit a switch and a fuse in the ('+') wire.
Use wires with minimum cross section of 6 mm
mm
2
(for 24 V).

5.6 Control panel

Fit the build-in flange with packing in the wall. See the drawing
in the section 'Principal dimensions' for the size of the holes.
Feed the cable through the flange to the toilet and connect it
with the cable on the toilet.
Fit the cover provided over the plug connection for protection.
Click the panel into the build-in flange, making sure that the O-
ring is fitted properly.
      ENGLISH
2
(for 12 V) or 4

110122.01

Publicidad

Tabla de contenido
loading

Tabla de contenido