Página 1
BATH MIXING PROGRAM PROGRAMME DU MITIGEUR POUR LA SALLE DE BAIN PROGRAMA MEZCLADORES BAÑO HI-FI Art. 63002 Art. 63004 Art. 63006 GESSI SpA Parco Gessi - 13037 Serravalle Sesia (Vercelli) ITALY Tel. +39 0163 454111 Fax +39 0163 459273 www.gessi.com - gessi@gessi.it...
Página 2
MUST NEVER BE EXCEEDED, as it may damage and/or cause ruptures and/or leakages and/or even break the product, and present a potential hazard and danger to safety, health and/or property. Following are the technical data with respect to the installation of Gessi plumbing products. ► W orkingpressureshouldnotbelowerthan0,5bar(7,25psi)andnotbehigherthan5bar(72Psi).In case of higher working pressure use a pressure reducer valve.
Página 3
Ci-dessous nous indiquons les données techniques concernant l’installation des produits sanitaires Gessi. ► L apressiondeservicenedoitpasêtreinférieureà0,5bar(7,25psi)etsupérieureà5bar(72Psi).En cas de pressions de service plus hautes utiliser une soupape de réduction de la pression.
Página 4
1 - ¡CUIDADO!! LES ROGAMOS QUE TENGAN EN CUENTA QUE NUNCA la presión y/o la temperatura máximaaconsejadaNOTIENEQUESERSUPERADA,yaquepodríadañary/ocausarrupturasy/o pérdidasy/oaveríasdelproductoy,porlotanto,representarunriesgoyunpeligropotencialpara la seguridad, la saludad y/o la propiedad. A continuación Les proporcionamos los datos técnicos relativosalainstalacióndelosproductosdegriferíaGessi. ► L apresióndeejercicionotienequeserinferiora0,5bar(7,25psi)ysuperiora5bar(72Psi).Encaso depresionesdeejerciciomayores,utilicenunaválvuladereduccióndelapresión. ►Presiónmáximadeensayodurantelainstalación:8bar(116psi). ► E vitengrandesdiferenciasdepresiónentrelaalimentacióndelaguafríayaquelladelaguacaliente. Lasdiferenciasdepresión,elaguaconunalatocontenidomineralylassustanciasjabonosaspueden...
Página 6
PRE-INSTALLATION INFORMATION - PRÉALABLES - PRELIMINARES ART. 63006...
Página 7
PRE-INSTALLATION INFORMATION - PRÉALABLES - PRELIMINARES Before installation and setting to work Attention! The feeding pipes have to be rinsed carefully before the installation of the device so that there won’t remain shavings, sealing or hemp residues, or other impurities inside the pipes. Through pipes not thoroughly rinsed or through the general water network, in the device foreign bodies can enter that could damage gaskets /o-ring. So filters should be installed also on the general system.
Página 8
PRE-INSTALLATION INFORMATION - PRÉALABLES - PRELIMINARES Before installation and setting to work Attention! The feeding pipes have to be rinsed thoroughly before the installation of the product, so that no shavings, welding or hemp residual or other dirt can be found in the pipes. Foreign bodies can enter the product through the rinsed pipes or the general water plant and could damage the washers/ring washers.Sofiltersshouldbeinstalledalsoonthegeneralsystem.Thewarrantydoesnotcovertheclaim onthisproductresultingfromfiltersnotbeinginstalledinthemainwatersystem....
Página 12
PRE-INSTALLATION INFORMATION - PRÉALABLES - PRELIMINARES Package content: A - Fastening plate B - Plate fastening screws C - Centring template D - Internal filters E-Adjustmenttemplate F - Head valve G - Prolongation kit for flow control H - Click system for flow control I-Flowrateadjustmenthandle L - Thermostatic cartridge M - Temperature control extension kit...
Página 13
INSTALLATION - INSTALLATION - INSTALACIÓN WARNING: graphic representation of the installation is based on the use of 1 outlet but it is the same also for all other cases mentioned before. ATTENTION: la représentation graphique de l’installation se base sur l’emploi de 1 sortie mais est la même également pour tous les autres cas mentionnés.
WORKING - FONCTIONNEMENT - FUNCIONAMIENTO Fig. 75 ONLY FOR ART. 63004-63006 Fig. 76 OPEN OPEN CLOSE PUSH PUSH PUSH Fig. 77 OPEN OPEN THAT IS NOT POSSIBLE PUSH PUSH...
Página 32
MAINTENANCE - ENTRETIEN - MANUTENCIÓN MAINTENANCE • Should it be necessary to replace one or more components, contact an authorized retailerorvisitWWW.GESSI.COM • Product maintenance should be made only by qualified staff ENTRETIEN • S’il est nécessaire de remplacer un ou plusieurs composants, contacter un centre autoriséouvisiterlesiteWWW.GESSI.COM...