GB
TECHNICAL CHARACTERISTICS
The heater is made up of:
• a tank protected inside by a layer of vitreous enamel, with a long-life anode for
protection against corrosion;
• an outer covering in painted steel;
• an insulation using high density polyurethane foam (without CFC) that reduces
heat losses;
• a fl ue gas hood to protect against the return of combustion products;
• a gas valve complete with:
an adjustable termostat with
a number of positions,
a safety system using a thermocouple,
a temperature limiter that stops the gas supply if operation is not correct;
• a tubular low-noise stainless steel burner, adaptable for use with all types of gas;
• piezoelectric ignition;
• a safety device to protect against the return of fl ue gas.
OVERALL SIZE
MODEL
Capacity (litres)
300
CATEGORY II
2H3+
Type B11 BS
26
HOT WATER OUTLET
(int. ø111)
HEATING TIME
t 25°C
275
40 min
for heaters arranged for operation with natural gas (methane) adaptable to
operation with LPG.
COLD WATER INLET
400
632
PILOT BURNER VISION
t 45°C
65 min
RECIRCULATION CIRCUIT G 3/4"
ANODE
Heat input kW
Useful rating kW
16
14