Connections - EAS ELECTRIC EMRH608VRT-W Manual De Instrucciones

Ocultar thumbs Ver también para EMRH608VRT-W:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Repeat this operation on the other side and on the vertical reference line,
checking that the three marks are leveled.
 Mark a point (3) on the horizontal line C, 80 mm to the vertical reference line.
 Repeat this operation on the other side , checking that the two marks are
leveled.
Fix the brackets (Optional):
 Drill at the marked points (1) (2) (3), using a ɸ 10 mm drill bit.
 Insert the Wall Plugs 11 into the holes (1) (2) (3).
 Fix the hood fixing bracket 20 with 3 screws 10 (5 x 50) supplied with the hood.
 Fix a Chimney fixing bracket 21 with 2 screws 10 (5 x 50) supplied with the hood.
Hook the hood body
 Open the panel.
 Remove the Metal grease filter using the handles provided.
 (Either) Hook the hood body to the bracket 20.
(Or) Hook the hood body to the screws 10 (5 x 50) at the points (2).
 Level the hood body itself.

CONNECTIONS

DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to
the chimney using either a flexible or rigid pipe ɸ 150 or ɸ
120 mm, the choice of which is left to the installer.
If to install a ɸ 120 mm air exhaust connection, insert the
reducer flange 3 on the hood body outlet.
Fix the pipe 4 in position using sufficient pipe clamps
(not supplied).
Remove possible charcoal filters.
Right
Wrong
8
V.6

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Emrh608vrt-nEmrh908vrt-wEmrh908vrt-n