Level 1
Level 2
3.1 Heat Mode
3.2 T_T4_Fresh_H
3.3 T4Hmax
3.4 T4Hmin
3.5 Dt1Sh
3.6 Reserved
3.7 T_Interval_H
3.8 T1Seth1
3 Heat Mode
For Serviceman
Setting
3.9 T1Seth2
3.10 T4H1
3.11 T4H2
3.12 Zone1 H-Emission
3.13 Zone2 H-Emission
3.14 T_Delay_Pump
5.1 Water Flow Temp.
5 Temp. Type
5.2 Room Temp.
For Serviceman
Setting
5.3 Double Zone
6 Room
For Serviceman
6.1Room Thermostat
Thermostat
7.1 dT1_IBH_ON
7.2 t_IBH_DELAY
7.3 T4_IBH_ON
7.4 dT1_AHS_ON
7.5 t_AHS_DELAY
7 Other Heating
For Serviceman
Source
7.6 T4_AHS_ON
7.7 IBH LOCATE
7.8 P_IBH1
7.9 P_IBH2
7.10 P_TBH
8.1 T1S_H.A._H
8 Holiday
For Serviceman
Setting
8.2 T5S_H.A._DHW
For Serviceman
9 Reserved
Reserved
10 Restore
10, 1 Restore Factory
For Serviceman
Factory Settings
Settings
118
EN
Menu
Menu
Level 3
Level 4
Double one:
0=Non,1=Yes
none/mode stting/one
zone/double zone
Pipe Loop=0; Buffer
Tank=1
Cod. 3541V941 - Rev. 00 - 09/2021
Description
Enable or disable the heating mode
The refresh time of climate related curves for
heating mode
The maximum ambient operating temperature for
heating mode
The minimum ambient operating temperature for
heating mode
The temperature difference for starting the unit
(T1)
Reserved
Time between stop and start of the compressor
in heating mode
The setting temperature 1 of climatic curve n°9
for heating mode.
The setting temperature 2 of climatic curve n°9
for heating mode.
The outdoor air temperature 1 of climatic curve
N°9 for heating mode.
The outdoor air temperature 2 of climatic curve
N°9 for heating mode.
The type of zone1 terminal for cooling mode:
0=FCU(fan coil unit): 1=RAD.(radiator):
2=FLH(floor heating)
The type of zone2 terminal for cooling mode:
0=FCU(fan coil unit): 1=RAD.(radiator):
2=FLH(floor heating)
Delay between pump activation and subsequent
compressor activation
Reserved
Reserved
Enable or disable 2 zone management
Select the type of control on the thermostat digital
input (0 = none, 1 = mode setting, 2 = one zone,
3 = double zone)
The temperature difference betw een T1S and T1
for starting the backup heater.
The time that the compressor has run before the
first backup heater turns on
Maximum outdoor air temperature below which
the backup heater can be activated
The temperature difference between T1S and
T1 for switching on the additional heating source
(gas boiler)
Compressor run time before activation of
additional heating source (gas boiler)
Maximum outside air temperature below which
the additional heating source (gas boiler) can be
activated
IBH backup heater installation location
PIPE LOOP = 0 if the heater is installed in series
with the heat pump;
BUFFER TANK = 1 if the heater is installed on
the plant tank
Power input of IBH1
Power input of IBH2
Power input of TBH
The target outlet water temperature for space
heating when in holiday aw ay mode
DHW boiler water temperature set point in
holiday mode
Reserved
Reset to factory parameters
OMNIA S 3.2
Lower
Upper
Unit of
Resolution
limit
limit
measure
0
1
1
/
0,5
6
0,5
hours
20
35
1
°C
-25
15
1
°C
2
10
1
°C
/
/
/
/
5
60
1
min
25
60
1
°C
25
60
1
°C
-25
35
1
°C
-25
35
1
°C
0
2
1
/
0
2
1
/
2
20
0,5
MIN
0
1
1
/
/
/
/
/
0
1
1
/
0
3
1
/
2
10
1
°C
15
120
5
MIN
-15
10
1
°C
2
20
1
°C
5
120
5
MIN
-15
30
1
°C
0
0
0
/
0
20
0,5
kW
0
20
0,5
kW
0
20
0,5
kW
20
25
1
°C
20
25
1
°C
/
/
/
/
Y
N
/
/
Default
value
1
0,5
25
-15
5
/
10
1
0,5
25
-15
0
0
2
1
/
0
0
5
30
-5
5
30
-5
0
0
0
2
25
25
/
N