Climatic Curves; Temperature Curves For Heating Mode And Eco Heating Mode; Climatic Curve 9 In Heating Mode Settable By The User - Ferroli OMNIA S 3.2 Manual De Instalación, Uso Y Mantenimiento
The climate related curves can be selected in the user interface. Once the curve is selected, the target water flow temperature in each mode is calculated by the curve.
It's possible to select curves even double zone function is enabled.
The relationship between outdoor temperature (T4/°C) and the target water temperature(T1S/°C) is described in the tables and pictures.
9.3.1 Temperature curves for heating mode and ECO heating mode
User terminals type (to setup on service menu Cool and heat mode setting)
Based on the type of user terminal selected the climatic curves set is limited, refer to the below table:
Terminal Type selected
FLH (radiant floor)
FCU (fancoil)
RAD (radiator)
CLIMATIC CURVES (WTS) HEATING MODE
T4 (T_outdoor_air) [°C]
T1S or T2S (Water flow Temp) [°C]
HEATING MODE (climatic curves set H1)
56
54
52
50
48
46
44
42
40
38
8
36
7
6
5
34
-20
-15
-10
-5
Climatic curve 9 in heating mode settable by the user
The climatic curve 9 is defined by 4 parameters that can be set by the user (T4H1, T4H2, T1SETH1, T1SETH2, refer to "9.2 Service parameters table" a pagina 117).