11. Troubleshooting
Fault
Motor does not start
or comes to a stop
(loose connection)
The motor perfor-
mance drops
Cutting is irregular
Notice! For protection, the motor is equipped with a thermal switch which cuts out when the
motor is overloaded and switches on again automatically after a short cooling period
Anl_GP_CM_36_41_Li_Solo_SPK13.indb 27
Anl_GP_CM_36_41_Li_Solo_SPK13.indb 27
GB
Possible causes
a) Motor terminals disconnected
b) The mower is standing in high
grass
c) The mower housing is clogged
d) Safety switch is not inserted
e) Battery is not correctly inserted
f) Insuffi cient or no contact between
the handle and the handle fastener
(Fig. 3 / Section 5).
a) The grass is too high or too damp
b) The mower housing is clogged
c) The blade is severely worn
d) Battery performance decrea-
sing
a) The blade is worn
b) Wrong cutting height
- 27 -
Remedies
a) Have repaired by the Customer
Service Center
b) Start in low grass or on an area that
has already been mowed; change
the cutting height if necessary
c) Clean the housing so that the blade
moves freely
d) Insert safety switch (see 6.)
e) Remove the battery and reinsert
(see 5.)
f) Undo the handle connection, check
the contacts for dirt and carefully
clean with a brush. Tighten the
handle connection (see 5).
a) Correct the cutting height
b) Clean the housing
c) Replace the blade
d) Check the battery performance
and charge the battery if necessary
(see 5.)
a) Replace or resharpen the blade
b) Correct the cutting height
26.08.2021 13:48:25
26.08.2021 13:48:25