If the ICM is not functioning properly or is out of order, please check the following before calling the
authorised service provider:
FAULT
The ICM does not
work.
The ICM does not
cool.
The ICM does not
cool.
18
Models Smart-300 [R290] LC, Smart-450L [R290] LC, Smart-450L
SZ T [R290], Smart-800 [R290] LC, Smart-900L SD [R290] LC,
Smart-900L HD [R290] LC, Smart-1300 HD [R290] LC and Smart-
1300 SD [R290] LC are equipped with HC refrigerant. All service
operations on cooling mechanism & gas charging should be
performed in a well- ventilated environment or in open air. Do
not smoke during maintenance.
UNPLUG THE COOLER PRIOR TO ANY MAINTENANCE OR SERVICE
OPERATIONS. REMOVE THE PLUG AND MAKE SURE THAT THE
OPERATOR CAN CHECK FROM ANY OF THE POINTS WHICH HE
HAS ACCESS THAT THE CABLE IS UNPLUGGED.
After maintenance operations, make sure that the grounding
connections are in place before assembling the covers. Make sure
you use the same fastening components and covers.
If any electrical components need to be replaced, use only the
appropriate components in the spare part list supplied by the
technical service department of Frigoglass.
Keep the glass door of the cooler closed during maintenance. If the
compressor needs to be replaced, you may need to use adequate
support to stabilize the cooler.
After maintenance operations make sure that the strain relief, which
supports the supply cord, is assembled properly.
POSSIBLE REASONS
Power cord not plugged in.
No power supply at the socket.
The ICM has recently been reloaded
with warm products. It takes some time
to cool warm products down.
The ICM is loaded in such a way that
the air circulation in the interior is getting
blocked.
The door does not seal properly.
Leakage in the cooling system.
HANDLING
Plug it in.
Check the outlet fuse.
Preferably, reload the ICM before night
closing.
Load the ICM according to the
standards you have been provided
with by the company.
Repair the doors for proper closing
(this type of repair should be
performed by an authorised
technician).
Repair the leakage (this type of repair
should be performed by an authorised
technician).