5. Transporting and storing the generating set

5.1. Transport and handling conditions
Before transporting the generating set, check that the bolts are correctly tightened, close the fuel tap (if fitted) and disconnect the
battery (if fitted). The generating set should be transported in its normal operating position; never lay it on its side. A pump unit should
be handled gently and brusque movements should be avoided. Ensure that the place where it is to be stored or used is carefully
prepared beforehand.
5.2. Storage conditions
This procedure for storing the generating set or protecting it over the winter must be respected if the generating set is not used for a
prolonged period (over 2 months). The generating set should be stored in its normal operating position; never lay it on its side.
Add preservative to the fuel tank.
Run the engine for 2 to 3 minutes.
Drain the oil.
Remove the spark plug (E – 2) and pour approximately 3 cl (1oz.) of fresh engine oil into the cylinder head(s).
Replace the spark plug(s)
Without starting the engine, slowly pull the starter-recoil reel handle (A - 10) until some resistance is felt
Disconnect the battery
Clean the generating set.
Cover the generating set with a protective cover to protect it from dust and store it in a clean and dry place.

6. Repairing minor faults

The generating set...
Does not start
Stops
Does not function normally
(noise, smoke, etc.)
Does not supply electrical
current
To contact the nearest agent, dial the numbers below (France only):
Check that:
The devices to be used have not been
connected prior to starting.
YES
The on/off control is at "ON".
YES
The oil level is correct.
YES
The fuel level is correct.
YES
The fuel tap is open.
YES
Maintenance has been correctly
performed on the generating set
components.
YES
Have the generating set checked by one
of our agents*.
Tripped circuit breaker(s).
YES
The connected devices and their power
cords are not faulty.
YES
Have the generating set checked by one
of our agents*.
Solutions to be applied:
Disconnect the devices then try to restart
the generating set.
NO
Move the on/off control to "ON" (see §
Starting).
NO
Top up with oil (see § Checking the oil
level).
NO
Fill up with fuel (see § Checking the fuel
level).
NO
Open the fuel tap
(see § Starting).
NO
Perform maintenance on the generating set
in accordance with the recommendations
NO
Check the capacity of the generating set
(see § Generating set capacity) and press
NO
the circuit breaker switches.
Try with another device and another power
NO
cord.