Special gas requirements (gas models sold in massachusetts)

COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS:
WARNING
Gas leaks may occur in your system, creating a dangerous situation.
– Gas leaks may not be detected by smell alone.
– Gas suppliers recommend you purchase and install a UL-approved gas detector.
Gas detector should be installed in accordance with the manufacturers
instructions.
• Range must be installed by a qualified plumber or gas fitter by the State of
Massachusetts.
• A T-handle manual gas valve MUST be installed in the gas supply line to your
range.
• If a flexible gas connector is used to install your range, multiple flexible gas lines
must not be connected in series.
Install_NX60T8755SS_AP_DG68-01326A-01_MES+EN.indb 17
Install_NX60T8755SS_AP_DG68-01326A-01_MES+EN.indb 17

Electrical requirements

WARNING
To reduce the risk of fire, electric shock, or personal injury:
All ranges
• Do not use an extension cord or adapter plug with this range.
• This range must be properly grounded.
• Check with a qualified electrician if you are in doubt as to whether your range is
properly grounded.
• Do not modify the plug provided with your range—if it doesn't fit the outlet, have
a proper outlet installed by a qualified electrician.
• All wiring and grounding must be done in accordance with local codes or, in the
absence of local codes, with the National Electrical Code, ANSI/NFPA No. 70 –
Latest Revision (for the U.S.) or the Canadian Electrical Code CSA C22.1 – Latest
Revisions and local codes and ordinances.
• Wiring diagram is located on the back of the range. (Inside of the cover back wire)
• This range is equipped with an electronic ignition system that will not operate if
plugged into an outlet that is not properly polarized.
Gas models
• All gas models are equipped with a power cord with an equipment-grounding
conductor and a grounding plug.
• A 120-Volt, 60-Hz, AC, approved electrical service with 20-amp circuit breaker or
time-delay fuse is required for all U.S. and Canadian models.
• Check for ¾-in (1.9-cm) UL-listed strain relief where the power cord comes out of
the range cabinet.
• Do not reuse a power supply cord from an old range or other appliance.
• The power cord electric supply wiring must be retained at the range cabinet with
a suitable UL-listed strain relief.
• A time-delay fuse or circuit breaker is also recommended.
English 17