Checking the flame quality:
All combustion flames need to be visually checked to determine their flame
quality.
1
2
Install_NX60T8755SS_AP_DG68-01326A-01_MES+EN.indb 23
Install_NX60T8755SS_AP_DG68-01326A-01_MES+EN.indb 23
1. Yellow tips on outer cones—Normal for LP
gas operation.
2. Yellow flames—Abnormal for any gas
operation; call for service.
NOTE
If burner flame looks like 2, the range
should not be used until it is serviced. Call
for service. Normal burner flames shall look
like 1 for LP gas operation.
Step 8. Final installation checklist
You have just completed installing your range. Make sure all controls are in the off
position and the flow of ventilation air to the range is unobstructed. The following
is a checklist to confirm your range is safely installed and ready for operation.
Gas Range Plug
Locking screw
Adjusting the oven burner air adjustment shutters
Air
adjustment
shutter
– Gas line has been properly connected to
the range. The gas has been turned on. All
connections have been checked for leaks.
– Range is plugged into the properly
grounded electrical receptacle.
– Approved anti-tip bracket is properly
installed and engaged with the range.
– Range is leveled and is firmly sitting on a
solid, level floor.
– Gas surface burners have been properly
assembled.
– All burners have been tested for proper
operation.
– FOR INSTALLER ONLY—Check and/or
adjust the broil and oven burner flames as
described on pages 22-23 in this manual.
All oven burners have an air adjustment
shutter. The purpose of the shutter is to
regulate the flow of air to the flames.
Properly adjusted flames should burn
steadily with approximately 1-in of blue
cone. The flames should never extend
past the edge of the burner baffles. Even
though these are preset at the factory, they
should be checked and, if needed, adjusted
periodically to ensure efficient operation.
English 23
2021-02-19 오후 6:49:31
2021-02-19 오후 6:49:31